United Kingdom version. Runs in kW, litres per second and pounds, and explains which UK motor efficiency class (IE2, IE3 or IE4) applies to the motor size the calculator picks. US version

Pump Power Calculator (UK, kW and £)

Work out pump shaft and electrical kW from flow and head, pick the next IEC motor size against the UK IE3 and IE4 rules, and cost the running hours in pounds.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Pump Power Calculator?

In Britain pumps and motors are bought in kW, not horsepower, and since 1 July 2021 a new three-phase motor from 0.75 kW to 1,000 kW with 2, 4, 6 or 8 poles must reach at least IE3 under the Ecodesign for Energy-Related Products and Energy Information Regulations 2021. From 1 July 2023 the band from 75 kW to 200 kW (2, 4 or 6 poles) must reach IE4. This version shows the shaft power, the next standard IEC rating and the running cost in pounds, so you can see which rule the motor you are about to specify falls under.

The default duty is a booster set for a small block of flats: 2.5 L/s against 30 m of head with a 60% efficient pump and an 85% efficient motor. The shaft needs 1.22 kW, so the next IEC size is 1.5 kW, and over 2,000 hours a year at an assumed 25p per kWh it costs about £720 to run. Replace the price with the unit rate from your own bill or supply contract.

  • Hydraulic, shaft and electrical power in kW and hp
  • Head or pressure-rise input with density-based conversion
  • Next standard IEC (kW) and NEMA (hp) motor size
  • Yearly energy and running cost in your currency
  • NPSH available with water vapour pressure from 0 to 100 °C
Read the guide: Pump Power, Head and Efficiency: From ρgQH to the Electricity Bill

Updated

How to use the Pump Power Calculator

  1. Enter the flow in L/s, L/min or m³/h and the total head in metres: static lift plus friction losses plus any pressure you need at the top.
  2. Take the pump efficiency from the maker's curve at your duty point; small pumps are usually less efficient than large ones, so do not borrow a figure from a bigger model.
  3. Enter the motor efficiency from its rating plate or data sheet rather than the class name, because the IE3 minimum depends on the size and number of poles.
  4. Set the hours per year and your unit rate in pounds per kWh to see the yearly cost.

Worked examples

Booster for a block of flats

Input

2.5 L/s, head 30 m, pump 60%, motor 85%, 2,000 h at £0.25/kWh

Output

Shaft 1.22 kW, next IEC size 1.5 kW; 1.44 kW drawn; 2,879 kWh, about £720 a year

A 1.5 kW three-phase motor is inside the 0.75 to 1,000 kW band, so a new one must be at least IE3.

Small house booster on low mains pressure

Input

1 L/s, head 25 m, pump 45%, motor 80%, 1,000 h at £0.25/kWh

Output

Shaft 0.54 kW, next IEC size 0.55 kW; 0.68 kW drawn; about £170 a year

Below 0.75 kW the GB rules ask for IE2 rather than IE3, and from July 2023 they also cover single-phase motors from 0.12 kW. Check the pump is allowed by your water company before boosting straight off the main.

Process pump in a factory

Input

20 L/s, head 35 m, pump 72%, motor 90%, 4,000 h at £0.22/kWh

Output

Shaft 9.52 kW, next IEC size 11 kW; 10.57 kW drawn; 42,298 kWh, about £9,306 a year

Here the pump loses 2.66 kW (9.52 kW at the shaft against 6.85 kW of water power) while the motor loses 1.06 kW, so pump selection at the duty point is where the bigger saving lies.

Background and insight

Hydraulic power is the rate of work done on the liquid: weight flow times head, P = ρgQH. In US units the same thing becomes water horsepower = gpm × ft × SG / 3960, the 3960 coming from 33,000 ft·lbf/min per hp divided by 8.33 lb per gallon. One mechanical horsepower is 745.7 W.

Pump efficiency comes from the manufacturer's curve at your duty point. Small end-suction pumps may reach 50 to 70% and large well-matched pumps 80 to 90%. Motor efficiency classes are set by IEC 60034-30-1, with IE3 (premium) motors roughly 85 to 96% depending on size. Standard motor ratings follow IEC 60072 in kW and NEMA MG 1 in hp.

Net positive suction head is about cavitation. NPSHa = (p_surface − p_vapour)/(ρg) + static suction head − suction losses. Hot water has a much higher vapour pressure (47.4 kPa at 80 °C versus 2.3 kPa at 20 °C), so a suction lift that works for cold water can starve a pump on hot water. Hydraulic Institute guidance (ANSI/HI 9.6.1) recommends an NPSH margin above NPSHr that depends on the application.

Common use cases

  • Motor sizing

    Get the shaft power and the next standard IEC or NEMA motor rating for a pump duty.

  • Energy audits

    Estimate yearly kWh and cost for an existing pump, and the saving from a more efficient pump or motor.

  • Cavitation checks

    Work out NPSH available on a lift or with hot water before choosing a pump.

  • Turning pressure into head

    Convert a gauge differential into metres or feet of head for a given liquid density.

Tips and limitations

  • Do not round the shaft power up twice. Pick the next IEC size above the shaft power, then add a margin only if the pump curve can run out to higher flows.
  • Demand in a building changes through the day, so ask whether a variable speed drive suits a booster before paying for a larger fixed-speed set.
  • Use the unit rate from your bill or contract; business tariffs and standing charges differ widely from household prices.
  • Head in metres converts to pressure at about 0.098 bar per metre, so a 30 m booster adds about 2.9 bar.

Sources and further reading

  1. The Ecodesign for Energy-Related Products and Energy Information Regulations 2021, Schedule 16, legislation.gov.uk. IE3 for three-phase motors from 0.75 to 1,000 kW from 1 July 2021; IE4 for 75 to 200 kW and IE2 for single-phase motors from 1 July 2023.
  2. The Water Supply and Sewerage Services (Customer Service Standards) Regulations 2008, regulation 17G, legislation.gov.uk. The 7 m static head minimum in England.
  3. The Water Supply and Sewerage Services (Customer Service Standards) Regulations 2008, regulation 10, legislation.gov.uk. The same 7 m static head minimum for Welsh water undertakers.
  4. IEC 60034-30-1: Efficiency classes of line operated AC motors (IE code), International Electrotechnical Commission. Definitions of the IE2, IE3 and IE4 classes.

Frequently asked questions

Do new motors in the UK have to be IE3?

Yes for most three-phase motors. Schedule 16 of the Ecodesign for Energy-Related Products and Energy Information Regulations 2021 requires IE3 from 1 July 2021 for three-phase motors rated from 0.75 kW up to and including 1,000 kW with 2, 4, 6 or 8 poles, with exceptions such as Ex eb increased safety motors.

Which motors need IE4?

From 1 July 2023 three-phase motors from 75 kW to 200 kW with 2, 4 or 6 poles must meet IE4, with exclusions including brake motors and certain explosion-protected motors. If the calculator suggests a 75 kW to 200 kW motor, expect an IE4 machine.

Should I size a UK pump motor in kW or hp?

In kW. British and European motors are rated by shaft output in kW on standard IEC steps such as 1.1, 1.5, 2.2, 3 and 4 kW. The hp figure is shown only for comparing with imported or older equipment.

How much does a pump cost to run per year?

Electrical kW x hours x your price per kWh. A booster drawing 1.44 kW for 2,000 hours uses 2,879 kWh, which is about £720 at 25p per kWh. Enter your own unit rate; it moves with your tariff.

How much head does a booster pump need to add?

Enough to cover the height of the highest outlet above the pump, the friction losses on the way, and the pressure you want at that outlet, less what the supply already provides. As a reference, water companies must keep at least 7 m of static head in the communication pipe: in England under regulation 17G of the Customer Service Standards Regulations 2008, and in Wales under regulation 10.

Is there an in-depth guide to the Pump Power Calculator?

Yes. “Pump Power, Head and Efficiency: From ρgQH to the Electricity Bill” covers the background, how it works, common pitfalls and worked examples. Read the full guide.