New Zealand version. Litres and °C, a 180 L cylinder with a 3 kW element, the 60 °C storage temperature advised for Legionella control, and cost from your power bill's c/kWh rate in NZ dollars. US version
Hot Water Cylinder Heat-Up Time and Cost (NZ)
How long a 3 kW element takes to heat a 135, 180 or 200 litre hot water cylinder to 60 °C, and what each heat-up costs at your c/kWh rate in NZ dollars.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Water Heating Time Calculator?
Most New Zealand homes without gas heat their water in an electric hot water cylinder, and the questions are how long it takes to come back up to temperature and what that costs. This version opens on a 180 litre cylinder heated from 12 °C to 60 °C by a 3 kW element: about 10.0 kWh goes into the water and it takes about 3 hours 24 minutes.
The 60 °C target is health advice. Healthify, whose Legionellosis page was reviewed by the National Public Health Service, says to keep a home hot water cylinder at 60 °C because Legionella bacteria cannot survive at 60 °C or above, and to have a mixing valve so the water at the tap is not hot enough to burn, especially where children or older adults live.
Power companies here charge in cents per kWh, and many offer a cheaper controlled rate for a hot water cylinder that the lines company can switch off at times of high demand. Enter the c/kWh from your bill as dollars (30 c/kWh is 0.30); the examples below use 30 c only as an illustration, not as an average price.
- Electric heaters in kW or gas and oil burners in BTU/h
- Heat-up time, energy in the water and energy purchased
- Cost per heat-up per kWh or per therm in a choice of currencies
- Recovery rate in gal/h or L/h at the chosen temperature rise
- Comparison table across common heater ratings
Updated
How to use the Water Heating Time Calculator
- Set the volume to the capacity on your cylinder's label.
- Enter the cold water temperature (colder in winter) and 60 °C as the target.
- Enter the element rating in kW from the cylinder label; only one element heats at a time.
- Enter your price per kWh in dollars: the anytime rate, or the controlled or night rate if your cylinder is on one.
Worked examples
180 L cylinder, 12 to 60 °C, 3 kW element
Input
180 L, 12 → 60 °C, 3 kW, 98%, 0.30 per kWh
Output
3 h 24 min, 10.04 kWh into the water, 10.25 kWh bought, NZ$3.07
At a 20 c/kWh controlled rate the same heat-up costs NZ$2.05. The time is the same either way, but a controlled cylinder may be switched off for a while at peak times, so allow for that before relying on a quick recovery.
The same cylinder on a winter morning
Input
180 L, 8 → 60 °C, 3 kW, 98%, 0.30 per kWh
Output
3 h 42 min, 11.10 kWh bought, NZ$3.33
Colder mains water in winter adds about 17 minutes and 26 cents to a full heat-up. A smaller 135 L cylinder from 12 °C takes 2 h 33 min and costs NZ$2.31, but holds less hot water.
Topping up after the morning showers
Input
180 L, 50 → 60 °C, 3 kW, 98%, 0.30 per kWh
Output
42 min 12 s, 2.11 kWh bought, NZ$0.63
A cylinder is rarely heated from cold. If the stored water has mixed down to about 50 °C, bringing it back to 60 °C takes about a fifth of a full heat-up.
Background and insight
The physics is the sensible heat equation, Q = m·c·ΔT, with the mass taken from the volume at the starting temperature. The calculator uses water density from the Kell equation, about 0.999 kg per litre at cold-water temperatures, and a specific heat of 4,186 J/kg·K. In US units this is the familiar plumbing rule: 8.34 lb per gallon times 1 BTU per lb per °F, so a 50 gallon tank needs about 417 BTU for every degree Fahrenheit.
Efficiency is where electric and gas heaters differ. An immersed electric element turns essentially all of its power into heat in the water; the 2% default allows for wiring and a little loss through the tank wall during heating. Gas burners lose heat up the flue, so the recovery efficiency on the rating plate of a residential gas tank is typically 76 to 82%, and condensing units reach above 90%. Kettles lose some heat from their body and lid and are often closer to 80 to 90%.
Recovery rate is how US manufacturers rate tank heaters: the gallons per hour they can heat through a given rise, often 90 °F. It equals the delivered BTU/h divided by 8.34 times the rise. Standby losses, scale on elements, cold water mixing during draws and stratification in the tank all make real heat-up times a little longer than this ideal figure.
Common use cases
Choosing a water heater
Compare element sizes or gas inputs for how quickly a tank recovers after a run of showers.
Off-grid and solar diversion
Estimate how much of a day a 1.5 or 3 kW immersion heater needs to heat a cylinder from surplus solar power.
Running cost per heat-up
Put a price on a full tank of hot water for electric resistance versus gas at local tariffs.
Process and lab water
Work out the warm-up time for a wash tank, a bath or a boiler loop with a known heater rating.
Tips and limitations
- Do not turn the thermostat below 60 °C to save power: 60 °C is the Legionella advice, and a mixing valve, not a lower cylinder temperature, is what keeps tap water from burning.
- Standing heat loss from the cylinder and pipes is not included here; insulating the cylinder and the pipes near it reduces that loss.
- This calculator models a resistance element. For a heat pump water heater, divide the kWh shown by the unit's COP (for example 3) for a rough energy figure; its heating time depends on its rated heat output, not its electrical input.
Sources and further reading
- Legionellosis (Legionnaires' disease), Healthify (Health Navigator Charitable Trust). Keep the home hot water cylinder at 60 °C; Legionella cannot survive at 60 °C or above; fit a mixing valve to avoid burns. Reviewed 11 October 2024 by the National Public Health Service.
- Understanding your power bill, Electricity Authority. Prices in cents per kWh; controlled rate for hot water cylinders.
- How to get cheaper power bills with a time-of-use plan, Electricity Authority
- University Physics Volume 2, 1.4: Heat Transfer, Specific Heat, and Calorimetry, OpenStax. Q = mcΔT.
Frequently asked questions
How long does a hot water cylinder take to heat up in NZ?
A 180 L cylinder with a 3 kW element takes about 3 hours 24 minutes from 12 °C to 60 °C, a 200 L one about 3 hours 47 minutes and a 135 L one about 2 hours 33 minutes. Winter mains water lengthens each of these.
What temperature should my hot water cylinder be set to?
60 °C. Healthify advises keeping a home hot water cylinder at 60 °C because Legionella bacteria cannot survive at 60 °C or above, with a mixing valve so the water that comes out of the tap does not burn. This version uses 60 °C as its target.
What is a controlled rate for hot water?
The Electricity Authority describes it as a lower price for power to controlled appliances such as hot water cylinders, in exchange for letting the network company switch the supply off at times of high demand.
How much does it cost to heat a hot water cylinder?
Multiply the kWh bought by your rate. A full 180 L heat-up from 12 °C uses about 10.25 kWh, so at 30 c/kWh it costs about NZ$3.07, and at a 20 c/kWh controlled rate about NZ$2.05. Your own rate is on your power bill.
Should I run my cylinder on a timer or a time-of-use plan?
The Electricity Authority suggests timers on hot water cylinders on a time-of-use plan, so they heat in the cheaper off-peak hours. Where the off-peak rate is lower and the cylinder holds enough for the day, heating it overnight costs less per heat-up; the heating time does not change.
Is there an in-depth guide to the Water Heating Time Calculator?
Yes. “How Long Does It Take to Heat Water? Tanks, Kettles and Recovery Rate” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like
Free, in-browser tools that pair well with this one.