Australia version. Uses the 125 mm sphere limit from the NCC Housing Provisions, millimetres throughout, and marks measured along a raked stair balustrade. US version

Balustrade Spacing Calculator (Australia, NCC)

How many balusters fit between deck or stair posts with equal gaps under the NCC 125 mm sphere rule, in millimetres, with marks along a raked stair balustrade.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Baluster Spacing Calculator?

In Australia a deck or stair barrier is a balustrade, and its openings must not let a 125 mm sphere through: NCC 2025 Housing Provisions 11.3.4(4), measured above the nosing line on a stair. A barrier is needed wherever it is possible to fall 1 m or more from the deck, verandah, stair or path to the surface below (11.3.3(1)).

Enter the clear distance between posts and the baluster width. On a 1,800 mm deck bay with 42 mm balusters, 11 balusters leave equal gaps of 111.5 mm at 153.5 mm centres. The calculator gives the first centre from the post and every mark, so the gaps come out equal at both ends.

Height is a separate check: 1 m above the floor of a deck, balcony or verandah and 865 mm above the stair nosings (11.3.4(2)). Where it is possible to fall more than 4 m, horizontal parts of the barrier between 150 mm and 760 mm above the floor must not make it climbable (11.3.4(8)).

  • Baluster count, equal gap, on-centre spacing and first position
  • IRC 4 in and 4-3/8 in, 100 mm and 125 mm presets or a custom limit
  • Stair mode from rise and run or degrees, with marks along the rail
  • Layout table of every centre and an elevation sketch
  • Multiple identical sections; imperial fractions or millimetres
Read the guide: Baluster Spacing and the 4 Inch Sphere Rule, With the Math

Updated

How to use the Baluster Spacing Calculator

  1. Keep metric units and the 125 mm (Australia NCC) limit.
  2. Enter the clear length between the inside faces of the posts and the baluster width.
  3. For a stair balustrade, choose stair rail and enter the riser and going, or the angle.
  4. Enter the number of identical bays to get the total balusters to buy.

Worked examples

Deck bay with 42 mm balusters

Input

1,800 mm between posts, 42 mm balusters, 125 mm limit

Output

11 balusters, 111.5 mm gaps, 153.5 mm centres, first centre 132.5 mm from the post

Six identical bays need 66 balusters. If a designer asks for a 100 mm limit instead, the same bay takes 12.

Stair balustrade at 180 over 250

Input

2,400 mm along the rail, 42 mm balusters, 180 mm riser and 250 mm going (35.8°), 125 mm limit

Output

11 balusters, 123.8 mm level gaps, 204.3 mm centres along the rail

Only 1.2 mm inside the limit. A custom 120 mm limit adds one baluster (12) and brings the gaps to 111.1 mm, a safer margin for timber that twists.

Wide decorative blades

Input

1,800 mm between posts, 65 mm blades, 125 mm limit

Output

9 blades, 121.5 mm gaps, 186.5 mm centres

Wider infill means fewer pieces for the same rule. Decorative balustrades are covered by the same 125 mm opening limit.

Background and insight

With n balusters of width b in a clear length L there are n + 1 gaps, so gap = (L - n b) / (n + 1). Requiring gap to be no more than the limit g gives n = ceil((L - g) / (b + g)). For 96 in between posts, 1-1/2 in balusters and a 4 in limit that is 17 balusters with 3.92 in gaps at 5.42 in on centre. Marking every centre from one post, rather than stepping off the spacing, stops rounding from adding up.

The IRC (Section R312.1.3) says required guards must not have openings that allow a 4 in sphere to pass, with two exceptions: 4-3/8 in on the open side of stairs and 6 in for the triangle formed by the riser, tread and bottom rail. England uses 100 mm (Approved Document K), as does the National Building Code of Canada, and Australia's NCC uses 125 mm. On a stair the balusters are vertical, so the clear gap is measured level: the calculator works in the level run (rail length x cos of the rake) and divides back by the cosine for marks along the rail.

Common use cases

  • Deck and porch railings

    Lay out balusters between posts with equal gaps that meet the 4 in rule.

  • Stair balustrades

    Convert level spacing into marks along a raked handrail or stringer.

  • Ordering balusters

    Count balusters for several identical sections in one go.

  • Metal and cable infill checks

    Check gaps for metal pickets or glass panels against a 100 mm or 125 mm limit.

Tips and limitations

  • Wire balustrades have their own deemed-to-satisfy tension and deflection rules in Housing Provisions 11.3.6; this calculator spaces rigid balusters and blades.
  • Measure the bay at rail height: posts are often slightly out of plumb.
  • On a high deck (a fall of more than 4 m), avoid horizontal rails and rails that act as footholds between 150 and 760 mm.
  • Check state and council requirements for pool fencing separately; it is a different set of rules.

Sources and further reading

  1. ABCB Housing Provisions, Part 11.3 Barriers and handrails, Australian Building Codes Board. NCC 2025: 11.3.3 (where barriers are needed), 11.3.4 (height, 125 mm openings, climbing) and 11.3.6 (wire barriers).
  2. National Construction Code, Australian Building Codes Board

Frequently asked questions

What is the maximum gap between balusters in Australia?

Openings must not permit a 125 mm sphere to pass through (NCC Housing Provisions 11.3.4(4)). On a stair the opening is measured above the nosing line of the treads. Aim for gaps a few millimetres under 125 mm.

When does a deck need a balustrade?

Where it is possible to fall 1 m or more from the trafficable surface to the surface beneath (Housing Provisions 11.3.3(1)). Measure from the deck to the ground below at the edge, not at the house.

How high does a deck balustrade have to be?

At least 1 m above the floor of a deck, balcony or verandah, and at least 865 mm above the nosings on a stair (Housing Provisions 11.3.4(2)).

What is the non-climbable zone for balustrades?

Where it is possible to fall more than 4 m, horizontal elements in the barrier between 150 mm and 760 mm above the floor must not facilitate climbing (11.3.4(8)). Vertical balusters avoid the problem.

How many balusters do I need for a 1.8 m deck section?

With 42 mm balusters and the 125 mm rule, 11 between posts 1,800 mm apart. Thinner 32 mm aluminium balusters or a stricter limit change the count, so enter your own sizes.

Is there an in-depth guide to the Baluster Spacing Calculator?

Yes. “Baluster Spacing and the 4 Inch Sphere Rule, With the Math” covers the background, how it works, common pitfalls and worked examples. Read the full guide.