Australia version. Metric throughout: pitch in degrees, a 90 mm wall top plate for the birdsmouth and 450 or 600 mm rafter centres, with member sizes left to AS 1684 as the NCC requires. US version

Rafter Length Calculator (Australia)

Rafter length in mm from the span and roof pitch in degrees, for pitched and skillion roofs on a 90 mm wall at 450 or 600 mm centres, with birdsmouth and cuts.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Rafter Calculator?

Australian roofs are specified by pitch in degrees, and stick-framed roofs sit their rafters on the top plate of a 90 mm stud wall. A gable at 22.5 degrees and a near-flat skillion at 5 degrees cover most of what a carpenter cuts by hand: verandahs, carports, pergola roofs, extensions and pitched roofs with a ridge board.

For an 8.4 m span at 22.5 degrees with a 35 mm ridge board, 450 mm of level eave and 140 mm deep rafters, each rafter is 5.014 m along the measuring line and a 12 m roof at 600 mm centres takes 21 a side. The birdsmouth on a 90 mm plate is 34 mm deep, a quarter of the rafter.

This tool does geometry only. NCC 2025 Volume Two (H1D6(4)) makes AS 1684.2 or AS 1684.4 the timber-framing standard in non-cyclonic areas and AS 1684.3 in cyclonic areas; the span tables there, for your wind classification, roof load and timber grade, set the rafter size and spacing.

  • Span or run input in feet-inches with fractions, or millimetres and metres
  • Pitch as x/12 or degrees with live conversion
  • Ridge deduction, overhang tail, plumb and seat cut settings
  • Birdsmouth heel, notch depth, height above plate and a one-third depth check
  • Rafter count, hip and valley factors and a framing square table
Read the guide: Rafter Length, Roof Pitch and the Birdsmouth Cut, Worked Out

Updated

How to use the Rafter Calculator

  1. Leave units on metric and enter the span between the outside faces of the wall top plates in metres.
  2. Enter the pitch in degrees, the ridge board thickness and the level eave overhang.
  3. Enter the rafter depth and the plate width the seat cut sits on: 90 mm for a 90 mm stud wall.
  4. Add the roof length and spacing (450 or 600 mm) to count rafters, and switch to a single slope for a skillion.

Worked examples

Pitched roof at 22.5 degrees

Input

8.4 m span, 22.5°, 35 mm ridge board, 450 mm eave, 140 mm deep rafters, 90 mm top plate, 12 m long at 600 mm

Output

Rafter 5.014 m (4.527 m to the plate line plus a 487 mm tail); notch 34 mm (25%); 42 rafters

At 450 mm centres the same roof takes 56 rafters (28 a side) and each jack rafter on a hip end steps by 487 mm instead of 649 mm.

Skillion extension at 5 degrees

Input

Single slope, 4.2 m run, 5°, no ridge, 600 mm overhang, 190 mm deep rafters, 90 mm plate, 6 m wide at 600 mm

Output

Rafter 4.818 m; heel 8 mm, notch 8 mm (4%); 11 rafters

At low pitches the birdsmouth almost disappears, so the fixing to the plate matters more than the notch. Roof sheeting makers publish minimum pitches for each profile; check yours before you commit to 5 degrees.

Carport gable at 25 degrees

Input

6.0 m span, 25°, 35 mm ridge, 600 mm overhang, 140 mm rafters, 90 mm plate, 9 m long at 600 mm

Output

Rafter 3.953 m; plumb cut 25°, seat cut 65°; 32 rafters

The cut length includes a 662 mm tail. Allow for the long point of the plumb cut when buying: at least 4.018 m of timber per rafter.

Background and insight

The slope factor sqrt(1 + (rise/12)²) converts any level distance into a distance along the rafter. It is the same number a framing square prints as "length of common rafter per foot of run": 13.42 in for 6/12 and 16.97 in for 12/12. For a regular hip roof, where both slopes share one pitch, the hip runs on the diagonal of a square, so its run is 16.97 in for every 12 in of common run and its length per foot is sqrt(288 + rise²), 18.00 in at 6/12. Jack rafters shorten by the spacing times the common slope factor, 17-7/8 in at 16 in centres on a 6/12 roof.

The ridge deduction is half the ridge thickness measured level, so it becomes 0.84 in along a 6/12 rafter for a 1-1/2 in ridge. Seat cut depth is limited in practice: the usual rule of thumb is to remove no more than a third of the rafter depth, and the IRC requires at least 1-1/2 in of bearing on wood (Section R802.6) and limits notches in sawn rafters. Rafter size and spacing for a given span come from the IRC R802 span tables or your local code.

Common use cases

  • Cutting a pattern rafter

    Get the plumb cut, seat cut and length to mark one rafter, test it on the building, then gang-cut the rest.

  • Ordering roof framing

    Count rafters and pick the stock length that covers the rafter plus the long point of the plumb cut.

  • Sheds, garages and porches

    Switch to shed mode for a single slope and use the run directly when the roof leans against a wall.

  • Checking hip and valley lengths

    Read the hip line length and jack rafter difference for a regular hip roof before laying out.

Tips and limitations

  • Many Australian houses have prefabricated trusses designed by the supplier; hand-cut rafters suit additions, verandahs, carports and cathedral ceilings.
  • The site wind classification (N or C class) decides the tie-down fixings as well as the member sizes in AS 1684.
  • Queensland replaces H1D6(4) with its own wording and timber species list, so check state variations in the NCC.
  • Cut one pattern rafter, check it at both ends of the roof, then mark the rest from it.

Sources and further reading

  1. NCC 2025 Volume Two, Part H1 Structure (H1D6 Framing), Australian Building Codes Board. H1D6(4): AS 1684.2 or AS 1684.4 for non-cyclonic areas, AS 1684.3 for cyclonic areas.
  2. ABCB Housing Provisions, Part 6.1 Scope of Section 6 Framing, Australian Building Codes Board. Points timber framing to H1D6(4) of Volume Two.

Frequently asked questions

Which standard sets rafter sizes in Australia?

AS 1684 Residential timber-framed construction. NCC 2025 Volume Two, H1D6(4), names AS 1684.2 or AS 1684.4 for non-cyclonic areas and AS 1684.3 for cyclonic areas. The calculator works out lengths and cuts; the AS 1684 span tables set the size.

Should rafters be at 450 or 600 mm centres?

Both are standard in Australia, and the span tables give different maximum spans for each. Closer centres let a smaller section span further and give more fixings for ceiling linings. Change the spacing in the calculator to see the rafter count for each.

How do I work out rafter length for a skillion roof?

Choose a single slope, enter the run from the low wall to the high wall, the pitch and the overhang. A 4.2 m run at 5° with a 600 mm overhang gives a 4.818 m rafter, because the slope factor at 5° is only 1.0038.

What does a 22.5 degree pitch equal as a ratio?

22.5° is a rise of 4.971 in 12, or about 414 mm rise per metre of run. The calculator converts degrees to rise per 12 for a framing square and back.

How deep should the birdsmouth be on a 90 mm wall?

With a full 90 mm seat at 22.5° the notch is 34 mm, a quarter of a 140 mm rafter. Keep the notch to a third of the depth or less, the common rule of thumb, and check the limit in AS 1684 for your member.

Is there an in-depth guide to the Rafter Calculator?

Yes. “Rafter Length, Roof Pitch and the Birdsmouth Cut, Worked Out” covers the background, how it works, common pitfalls and worked examples. Read the full guide.