Australia version. Millimetres, checked against NCC Housing Provisions 11.2.2: riser 115 to 190 mm, going 240 to 355 mm, 2R + G of 550 to 700 mm and 2 to 18 risers per flight. US version

Stair Calculator (Australia, NCC)

Risers, goings and stringer length in mm from the floor-to-floor height, checked against the NCC: riser 115 to 190 mm, going 240 to 355 mm, 18 risers per flight.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Stair Calculator?

Stairs in Australian houses follow NCC Housing Provisions Part 11.2. Table 11.2.2a allows risers of 115 to 190 mm and goings of 240 to 355 mm, with the slope relationship 2R + G between 550 and 700 mm, and each flight must have between 2 and 18 risers. Headroom over the stair is at least 2.0 m above the nosing line.

The 18-riser limit is where taller homes run into trouble. A 3.3 m floor-to-floor height at a 190 mm maximum riser gives 18 risers of 183.3 mm, which just fits in one flight. At 3.5 m it becomes 19 risers, so the stair needs a landing to split it into two flights.

Enter the floor-to-floor height and your riser and going. The tool counts risers, checks them against the NCC table, and gives the total run and stringer length.

  • Risers, treads, total run, stringer length and angle from the total rise
  • Checks against IRC R311.7 riser, tread and nosing limits, plus 2R + T comfort
  • Fit-to-run mode for stairs in a fixed space
  • Scale side-view drawing and one-more, one-fewer riser comparison
  • Inches or millimetres; copy the layout or share a link
Read the guide: Roof Pitch, Stair Layout, AC Sizing and Running Costs Explained

Updated

How to use the Stair Calculator

  1. Measure finished floor to finished floor in mm.
  2. Choose "NCC Housing Provisions (Australia)" under "Check against".
  3. Set the maximum riser (190 mm or less) and the going.
  4. If the flight has more than 18 risers, plan a landing.

Worked examples

Two-storey house

Input

Total rise 2,850 mm, maximum riser 190 mm, going 250 mm

Output

15 risers of 190 mm, 14 goings of 250 mm; run 3,500 mm; 2R + G = 630 mm; angle 37.2°

Every check passes. A 260 mm going would make it a little gentler at the cost of 140 mm more run.

High-ceiling home that needs a landing

Input

Total rise 3,500 mm, maximum riser 190 mm, going 250 mm

Output

19 risers of 184.2 mm; fails the 18 risers per flight limit

Riser, going and 2R + G all pass, but one flight cannot have 19 risers. Split it with a landing, for example 10 and 9.

Deck stairs

Input

Total rise 1,200 mm, maximum riser 180 mm, going 280 mm

Output

7 risers of 171.4 mm, 6 goings of 280 mm; run 1,680 mm; 2R + G = 623 mm

Deck stairs are stairways under the NCC too, and the deck needs a barrier where it is possible to fall 1 m or more (NCC Housing Provisions 11.3.3).

Background and insight

The code numbers come from IRC section R311.7: R311.7.5.1 limits riser height to 7 3/4 inches (196 mm), R311.7.5.2 sets a 10 inch (254 mm) minimum tread, R311.7.2 requires 6 feet 8 inches of headroom measured from the sloped line of the nosings, and riser heights within a flight may differ by no more than 3/8 inch. Commercial stairs under the IBC are stricter, at a 7 inch maximum riser and 11 inch minimum tread, and local amendments are common, so confirm with your building department.

The 2R + T rule goes back to François Blondel, a 17th-century French architect who tied step size to the length of a natural stride; modern practice puts the target at 24 to 25 inches (610 to 635 mm). A 7 inch riser with an 11 inch tread scores 25, a classic comfortable stair. Steeper stairs save floor space but feel abrupt going down, which is when most stair falls happen.

Common use cases

  • Deck and porch stairs

    Lay out stringers for the drop from a deck to grade, with the riser count and cut dimensions.

  • Basement and loft stairs

    Check whether a replacement stair will fit the existing opening and pass inspection.

  • Planning a renovation

    See how much floor space a new stair needs before moving walls.

  • Checking an existing stair

    Measure a stair that feels steep and see which rule it breaks.

Tips and limitations

  • Risers must not have openings that let a 125 mm sphere pass between treads (11.2.2).
  • Goings and risers must be constant: no more than 5 mm between adjacent steps and 10 mm across a flight.
  • Spiral stairs have their own limits in Table 11.2.2a.

Sources and further reading

  1. Part 11.2 Stairway and ramp construction (NCC 2025 Housing Provisions), Australian Building Codes Board. 11.2.2 and Tables 11.2.2a and 11.2.2b.
  2. Part 10.3 Room heights (NCC 2025 Housing Provisions), Australian Building Codes Board. 2.0 m above the nosing line of stairway treads.

Frequently asked questions

What is the maximum riser height in Australia?

190 mm for a stairway other than a spiral, under NCC Housing Provisions Table 11.2.2a. The minimum is 115 mm. Stairs serving only non-habitable rooms used infrequently, such as attics, may use Table 11.2.2b (up to 225 mm).

What is the minimum going for stairs under the NCC?

240 mm, and no more than 355 mm, for stairs other than spirals. The going must also give a 2R + G of 550 to 700 mm with the riser you choose.

How many steps can a stair have before a landing?

No more than 18 risers in a flight, and at least 2. Winders count toward the 18.

How much headroom does a staircase need?

At least 2.0 m measured vertically above the nosing line of the treads, under NCC Housing Provisions 10.3.1.

Can my stairs have open risers?

Yes, as long as the openings do not let a 125 mm sphere pass through between the treads.

Is there an in-depth guide to the Stair Calculator?

Yes. “Roof Pitch, Stair Layout, AC Sizing and Running Costs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.