Australia version. Covers the commercial grade 4.6 and high-strength 8.8 bolts used in Australia, works in Nm, and compares results with the AS 4100 minimum tensions for fully tensioned structural bolts. US version

Bolt Torque Calculator (Grade 4.6 and 8.8, Nm)

Tightening torque in Nm and clamp force for metric grade 4.6, 8.8 and 10.9 bolts to AS 4291.1, with nut factors, a size chart and AS 4100 bolt tension checks.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Bolt Torque Calculator?

Australian hardware and steel suppliers sell metric bolts in two main strengths: grade 4.6 commercial bolts and grade 8.8 high-strength bolts, with 10.9 and 12.9 for machine work. Their mechanical properties are set by AS 4291.1, which is identical to ISO 898-1, and structural 8.8 assemblies (bolt, nut and washer together) are made to AS/NZS 1252.1. This version starts on an M20 grade 8.8 bolt, the common size in light structural steelwork: at 75% of proof load with dry threads it needs 440.6 N·m.

For structural joints the tightening method matters as much as the number. AS 4100 defines snug tight, used for the 8.8/S category, as the tightness reached by a few impacts of an impact wrench or the full effort of a person using a standard podger spanner. Fully tensioned 8.8/TF and 8.8/TB bolts must reach the AS 4100 minimum bolt tension (145 kN for M20, 210 kN for M24, as tabulated in TMR Technical Note 62 of 2015), which is close to the full proof load of the bolt. On its own projects Queensland Transport and Main Roads (TMR) uses load-indicating washers, or a wrench calibrated in a bolt tension meter where washers cannot be used, and does not accept the part-turn method.

Use the calculator to see why. Enter the torque, choose the thread condition, and read the clamp force it would give: the answer moves by tens of kilonewtons as the nut factor changes, which is why the tension, not the torque, is what gets specified and checked.

  • Metric coarse M3 to M36, UNC and UNF 1/4 to 1-1/2 inch
  • ISO 898-1 classes 4.6, 5.6, 8.8, 10.9, 12.9 and SAE J429 Grades 5 and 8 with size-dependent proof stress
  • Nut factor presets from Shigley Table 8-15, or a custom K
  • Torque from target preload, or preload from a torque; percent of proof and yield shown
  • Full torque chart for the series, copy and share link
Read the guide: Bolt Tightening Torque and Preload: T = KFd in Practice

Updated

How to use the Bolt Torque Calculator

  1. Pick the thread series: metric coarse, UNC or UNF. The grade list switches between ISO property classes and SAE grades.
  2. Choose the size and the property class or grade marked on the bolt head.
  3. Set the thread condition. Use dry, finish unknown (K = 0.20) if you are unsure, or enter a measured K.
  4. Choose Torque for a target preload and enter the percentage of proof load, or Preload from a torque and enter the wrench setting.
  5. Read the torque, preload and bolt stress, and use the chart below for other sizes at the same settings.

Worked examples

M24 grade 8.8 at the TMR figure of about 800 N·m

Input

Preload from a torque: 800 N·m, M24 x 3, grade 8.8; custom K = 0.16 (lubricated) and K = 0.20 (dry)

Output

K = 0.16: 208.3 kN (98.5% of proof). Dry: 166.7 kN (78.8% of proof)

TMR Technical Note 62 says a typical M24 structural bolt needs about 800 N·m to fully tension. With a lubricated nut factor of 0.16 that reaches roughly the AS 4100 minimum of 210 kN; on dry threads the same torque falls about 20% short. Hence calibration against measured tension.

M20 grade 8.8 at full proof load

Input

M20 x 2.5, grade 8.8, dry (K = 0.20), 100% of proof

Output

Proof load 146.9 kN; 587.5 N·m

The AS 4100 minimum tension for a fully tensioned M20 bolt is 145 kN, essentially the whole proof load. A general 75% torque chart value (440.6 N·m) would leave a TB or TF joint under-tensioned.

M16 grade 4.6 commercial bolt

Input

M16 x 2, grade 4.6, dry (K = 0.20), 75% of proof

Output

Preload 26.4 kN; 84.6 N·m

Less than 40% of the torque an 8.8 bolt of the same size takes (218.1 N·m). An 8.8 chart value on a 4.6 bolt stretches it past yield.

Background and insight

Proof load is the tensile force a bolt must carry without permanent set, and it is the usual basis for preload. It is the tensile stress area times the proof stress. ISO 898-1 gives proof stresses of 580 MPa for class 8.8 up to M16 (600 MPa above), 830 MPa for 10.9 and 970 MPa for 12.9. SAE J429 gives 85 ksi for Grade 5 from 1/4 to 1 inch (74 ksi from over 1 to 1-1/2 inch) and 120 ksi for Grade 8. Stress areas come from the thread geometry: As = π/4 (d − 0.9382P)² for ISO metric threads and At = 0.7854 (D − 0.9743/n)² for Unified threads in ASME B1.1, which reproduce the tabulated 58.0 mm² for M10 and 0.1419 in² for 1/2-13.

The nut factor K is not a friction coefficient; it lumps thread friction, underhead friction and thread geometry into one empirical number. Shigley's Mechanical Engineering Design (Table 8-15, from Bowman's Fastener Facts) lists 0.30 for non-plated black finish, 0.20 for zinc-plated, 0.18 for lubricated, 0.16 for cadmium-plated and 0.12 with anti-seize compound, and suggests K = 0.20 when the condition is unknown. Shigley recommends preload of 75% of proof load for connections that will be reused and 90% for permanent ones.

Because friction varies, torque is an imprecise way to set preload. Two bolts tightened to the same torque can differ in clamp force by 25% or more. Where that matters, engineers use turn-of-nut, direct tension indicators, ultrasonic measurement or torque-angle methods, and VDI 2230 for a full joint analysis.

Common use cases

  • Machine assembly

    Set wrench values for flanges, brackets and covers when the drawing gives a bolt grade but no torque.

  • Automotive and equipment repair

    Check whether a torque from a manual is in a sensible range for the bolt size and grade fitted.

  • Writing a torque table

    Generate a chart for a whole thread series at the lubrication and preload your shop actually uses.

  • Diagnosing loose or broken bolts

    Back out the preload a given torque produced to see whether a joint was under- or over-tightened.

Tips and limitations

  • Check the head: grade 8.8 bolts are marked 8.8, and AS/NZS 1252.1 structural assemblies carry identification marks on the bolt head, the nut and the washer. Treat an unmarked bolt as unknown strength: do not use it in a structural or safety-critical joint. Class 4.6 is the lowest class the calculator offers, not a guaranteed minimum.
  • For 8.8/TF and 8.8/TB joints, follow the project specification and AS 4100 (or AS/NZS 5131 for fabrication and erection). TMR requires washers under both the bolt head and the nut and at least one full thread past the nut.
  • Load-indicating washers are checked with a feeler gauge. TMR accepts a bolt when the gauge cannot be pushed in at half the available gaps or more, and rejects it if no gap is left at all, because it has been overtightened.
  • TMR has bolt threads lubricated with a stick wax before the nut goes on. For waxed threads enter a nut factor below the dry 0.20, then confirm the wrench setting by calibration.

Sources and further reading

  1. Technical Note 62: Assembly and Tensioning of High Strength Bolts and Nuts, Part 1: Class 8.8, Queensland Department of Transport and Main Roads. AS 4100 bolting categories, snug tight definition, minimum bolt tensions, accepted tensioning methods and the 800 N·m M24 figure.
  2. AS 4291.1:2015 Mechanical properties of fasteners made of carbon steel and alloy steel, Bolts, screws and studs, Standards Australia. Identical adoption of ISO 898-1:2013.
  3. IS 1367 (Part 3):2002 Technical supply conditions for threaded steel fasteners, Part 3: Mechanical properties of fasteners made of carbon steel and alloy steel, bolts, screws and studs, Bureau of Indian Standards (Public.Resource.Org copy). Identical with ISO 898-1:1999; Table 3 lists the same proof stresses (225, 580/600, 830 and 970 N/mm²).
  4. ISO 898-1:2013 Mechanical properties of fasteners made of carbon steel and alloy steel, Part 1, International Organization for Standardization. Proof stresses for property classes 4.6 to 12.9.

Frequently asked questions

What torque does an M20 grade 8.8 bolt need?

For general machine work at 75% of proof load with dry threads, about 441 N·m (110.2 kN clamp). For a structural 8.8/TB or 8.8/TF joint the target is the AS 4100 minimum tension of 145 kN instead, which is about 580 N·m dry (0.20 x 145 kN x 20 mm) and should be set by a calibrated method, not a chart.

What is the difference between 8.8/S, 8.8/TB and 8.8/TF bolting?

They are AS 4100 bolting categories. 8.8/S bolts are snug tight. 8.8/TB bolts are fully tensioned and carry load in bearing; 8.8/TF bolts are fully tensioned and carry load by friction between the plies.

What does snug tight mean in AS 4100?

The tightness reached by a few impacts of an impact wrench or by the full effort of a person using a standard podger spanner, enough to bring the plies into firm contact. It has no torque value.

Is grade 4.6 or 8.8 stronger?

Grade 8.8. Its proof stress is 580 MPa up to M16 against 225 MPa for 4.6, so an 8.8 bolt of the same size carries about 2.6 times the clamp force.

Can I tension structural bolts with a torque wrench?

Only with a wrench calibrated for that batch of bolts, nuts and lubricant against a bolt tension meter, or with load-indicating washers to confirm the tension. An uncalibrated torque figure can miss the AS 4100 minimum by 20% or more, as the M24 example shows.

Which Australian Standard covers bolt grades?

AS 4291.1 sets the mechanical properties of carbon and alloy steel bolts, screws and studs by property class and is identical to ISO 898-1. AS/NZS 1252.1 covers high-strength structural bolt assemblies in grade 8.8 from M12 to M36.

Is there an in-depth guide to the Bolt Torque Calculator?

Yes. “Bolt Tightening Torque and Preload: T = KFd in Practice” covers the background, how it works, common pitfalls and worked examples. Read the full guide.