Australia version. Works in metres head and kPa, the units Australian utilities and plumbers use, with Sydney Water's published minimum and typical mains pressures as reference points. US version

Hydrostatic Pressure Calculator (Australia): Head to kPa

Convert metres head to kPa as Australian water utilities quote it, check the minimum pressure at your connection and see why a gravity-fed tank needs a pump.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Hydrostatic Pressure Calculator?

Australian water utilities describe mains pressure in metres head, the height water would rise in a vertical pipe, while pumps, gauges and plumbing fittings are rated in kPa. This version converts between them: each metre of fresh water is 9.81 kPa. Sydney Water's Operating Licence requires at least 15 metres head at the connection to a property, which is 147 kPa.

The same utility reports a network average of 52 metres head, about 510 kPa, with most properties receiving between 15 and 65 metres and some above 100 metres. That range explains why one house has a weak shower while another may need a pressure limiting valve, and the calculator shows where your own figure sits in kPa or bar.

It also answers the rainwater tank question. A tank on a stand 2.2 m above a garden tap delivers only 21.6 kPa with nothing flowing, a seventh of the minimum mains pressure, which is why Sydney Water says most tanks need a pump to match drinking water pressure.

  • Gauge and absolute pressure at any depth, p = ρgh
  • Presets for fresh water, seawater, brine, fuels, oil and mercury, plus custom density
  • Editable atmospheric pressure and a choice of Pa, kPa, bar, MPa or psi
  • Force and centre of pressure on a vertical rectangular wall or gate, with a diagram
  • Metric and US units with in-place conversion, copy and share
Read the guide: Hydrostatic Pressure at Depth and the Force on Walls and Gates

Updated

How to use the Hydrostatic Pressure Calculator

  1. Enter the head in metres: the height of the water surface above the outlet, or the pressure your utility quotes in metres.
  2. Keep the liquid on fresh water, or pick another fluid.
  3. Leave "Show pressure in" on kPa, or switch to bar or psi to match a gauge or pump label.
  4. For the load on a tank wall, a pit lid or a gate, fill in the width and height in the lower panel.

Worked examples

Sydney Water's minimum at the connection

Input

Fresh water, head 15 m

Output

147.1 kPa (1.47 bar) gauge

This is the lowest static pressure Sydney Water must supply at the point of connection. Friction in your service pipe and fittings reduces what is left at a tap while water flows.

Average Sydney network pressure

Input

Fresh water, head 52 m

Output

509.9 kPa (5.1 bar) gauge

The average sits towards the top of the 15 to 65 metre range most homes see. Sydney Water reduces pressure gradually in parts of the network because high pressure leads to pipe breaks and leaks.

High-pressure property

Input

Fresh water, head 100 m

Output

980.7 kPa (9.8 bar) gauge

Some customers receive more than 100 metres head. At these pressures, ask a plumber whether a pressure limiting valve is needed to protect taps, hoses and appliances.

Rainwater tank on a stand

Input

Fresh water, head 2.2 m

Output

21.6 kPa (0.22 bar) gauge

Enough to fill a watering can or run a hose slowly, nowhere near enough for a shower or washing machine. Sydney Water recommends a small external pump for simple household use.

Background and insight

The relation comes from a force balance on a small column of fluid: the pressure at the bottom must support the weight of the column above it, so dp/dz = ρg. With constant density this integrates to p = p_atm + ρgh. Pascal described the consequences in the 1640s, including the hydrostatic paradox that a tall thin column exerts the same bottom pressure as a wide tank of the same depth.

For a plane surface, the resultant force equals the pressure at the centroid times the area, F = ρg h_c A. The force acts lower than the centroid, at y_cp = h_c + I_c/(h_c A), because pressure is higher at the bottom. For a rectangle starting at the surface that is two-thirds of the way down. Gauge pressure is used because atmospheric pressure usually acts on both faces of a wall and cancels.

Seawater density depends on salinity and temperature, usually between about 1020 and 1030 kg/m³ at the surface, so 1025 kg/m³ is a common design value. Standard gravity is 9.80665 m/s² and a standard atmosphere is 101.325 kPa (14.696 psi).

Common use cases

  • Tank and pipe pressure ratings

    Find the static pressure at the bottom of a tank, a riser or a vertical pipe run.

  • Walls, gates and hatches

    Get the resultant force and where it acts for structural or hinge design.

  • Level and pressure sensors

    Convert a transmitter reading to liquid depth for a known density, or the reverse.

  • Diving and marine work

    Pressure at depth in seawater in bar, psi and atmospheres absolute.

Tips and limitations

  • To turn a utility's figure into kPa, multiply metres head by 9.81; for a quick estimate, multiply by 10.
  • Measure head vertically. A long horizontal run adds friction, not head.
  • A pressure gauge on an outside tap with everything else turned off reads static pressure, which this calculator matches; read it again with a tap running to see the friction loss.
  • Head depends on height below the supply reservoir, so a house high up on a hill and one in the valley below can see very different pressures from the same network.

Sources and further reading

  1. Water Pressure Management Program, Sydney Water. Minimum 15 metres head at the point of connection; network average 52 metres; most properties 15 to 65 metres, some above 100.
  2. Rainwater tanks, Sydney Water. Most tanks need a pump to match drinking water pressure.
  3. CODATA value: standard acceleration of gravity, National Institute of Standards and Technology. 9.80665 m/s², used for p = ρgh.

Frequently asked questions

How many kPa is 1 metre head?

About 9.81 kPa for fresh water, so 10 metres head is 98.1 kPa and 50 metres is about 490 kPa. In bar, divide kPa by 100.

What is the minimum water pressure in Sydney?

Sydney Water's Operating Licence requires it to supply at least 15 metres head at the point of connection to a property, about 147 kPa. Other utilities publish their own service standards, so check your water retailer's customer contract.

What is normal mains water pressure?

Sydney Water reports a network average of 52 metres head (about 510 kPa), with most properties between 15 and 65 metres (147 to 637 kPa) and some above 100 metres.

Why does water from my rainwater tank barely trickle?

Because the head is small. A tank whose water surface is 2.2 m above a tap gives about 21.6 kPa, compared with at least 147 kPa from the mains in Sydney. A pump, or raising the tank much higher, is needed for normal flow.

Why do water utilities measure pressure in metres?

Because head relates directly to the height of reservoirs and hills in the network: a reservoir 40 m above a house gives about 40 m of head, less pipe losses. Sydney Water describes head as the height water rises vertically.

Is there an in-depth guide to the Hydrostatic Pressure Calculator?

Yes. “Hydrostatic Pressure at Depth and the Force on Walls and Gates” covers the background, how it works, common pitfalls and worked examples. Read the full guide.