United Kingdom version. Litres and °C, a 3 kW immersion heater, prices in pounds at the Ofgem cap unit rate for October to December 2026, and the HSE 60 °C storage guidance. US version
Immersion Heater Heating Time and Cost (UK)
How long a 3 kW immersion heater takes to heat a hot water cylinder to 60 °C and what each heat-up costs at the Ofgem price cap unit rate, or for a kettle.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Water Heating Time Calculator?
In a British home the question is usually how long the immersion heater takes to heat the cylinder, and what that costs. This version opens on a 150 litre cylinder heated from 10 °C mains water to 60 °C by a 3 kW element: 8.72 kWh goes into the water, it takes about 2 hours 57 minutes and costs £2.34 at the price cap unit rate of 26.32p per kWh.
The 60 °C target is not arbitrary. HSE's legionella guidance, written for people who manage hot and cold water systems, says hot water should be stored at 60 °C at least, so a cylinder that is only ever heated to 45 or 50 °C saves a little energy at a real health cost. Water that hot can scald at the tap, which is why Approved Document G covers hot water safety in new homes and why a thermostatic mixing valve sits between the cylinder and the bath.
Your own unit rate may differ from the cap: fixed tariffs, regional rates and Economy 7 or other time-of-use tariffs all change the cost line, so type the rate from your bill. The time does not change with the tariff.
- Electric heaters in kW or gas and oil burners in BTU/h
- Heat-up time, energy in the water and energy purchased
- Cost per heat-up per kWh or per therm in a choice of currencies
- Recovery rate in gal/h or L/h at the chosen temperature rise
- Comparison table across common heater ratings
Updated
How to use the Water Heating Time Calculator
- Pick US or metric units. Switching converts the volume and temperatures already entered.
- Enter the volume of water and its starting and target temperatures.
- Choose electric and enter the heater power in kW, or gas and enter the burner input in BTU/h.
- Adjust the efficiency if you know it, and enter your price per kWh or per therm with a currency symbol.
- Read the time, energy, cost and recovery rate, and compare heater sizes in the table below.
Worked examples
150 L cylinder, 10 to 60 °C, 3 kW immersion
Input
150 L, 10 → 60 °C, 3 kW, 98%, 26.32p/kWh
Output
2 h 57 min, 8.72 kWh into the water, 8.90 kWh bought, £2.34
The cap rate applies from 1 October to 31 December 2026. On an off-peak rate half as high, the cost halves; the time stays the same.
210 L cylinder from cold, then a top-up
Input
210 L, 10 → 60 °C, 3 kW; then 210 L from 45 → 60 °C
Output
4 h 9 min and £3.28 from cold; 1 h 14 min and £0.97 for the top-up
A cylinder is rarely heated from cold. After a morning of showers the stored water may be mixed down to around 45 °C, and topping it back up takes about a third of the full heat-up.
A full 1.7 L kettle versus one mug
Input
1.7 L, 10 → 100 °C, 3 kW, 90%; then 0.5 L
Output
3 min 57 s and 5.2p; 1 min 10 s and 1.5p
At 230 V a 3 kW kettle draws about 13 A (3,000 / 230 = 13.0). Boiling only what you need is the biggest saving.
Background and insight
The physics is the sensible heat equation, Q = m·c·ΔT, with the mass taken from the volume at the starting temperature. The calculator uses water density from the Kell equation, about 0.999 kg per litre at cold-water temperatures, and a specific heat of 4,186 J/kg·K. In US units this is the familiar plumbing rule: 8.34 lb per gallon times 1 BTU per lb per °F, so a 50 gallon tank needs about 417 BTU for every degree Fahrenheit.
Efficiency is where electric and gas heaters differ. An immersed electric element turns essentially all of its power into heat in the water; the 2% default allows for wiring and a little loss through the tank wall during heating. Gas burners lose heat up the flue, so the recovery efficiency on the rating plate of a residential gas tank is typically 76 to 82%, and condensing units reach above 90%. Kettles lose some heat from their body and lid and are often closer to 80 to 90%.
Recovery rate is how US manufacturers rate tank heaters: the gallons per hour they can heat through a given rise, often 90 °F. It equals the delivered BTU/h divided by 8.34 times the rise. Standby losses, scale on elements, cold water mixing during draws and stratification in the tank all make real heat-up times a little longer than this ideal figure.
Common use cases
Choosing a water heater
Compare element sizes or gas inputs for how quickly a tank recovers after a run of showers.
Off-grid and solar diversion
Estimate how much of a day a 1.5 or 3 kW immersion heater needs to heat a cylinder from surplus solar power.
Running cost per heat-up
Put a price on a full tank of hot water for electric resistance versus gas at local tariffs.
Process and lab water
Work out the warm-up time for a wash tank, a bath or a boiler loop with a known heater rating.
Tips and limitations
- Many cylinders have two immersion elements, a top one for a quick top-up and a bottom one for a full heat-up. Only one runs at a time, so use a single 3 kW rating.
- Mains water in winter can be well below 10 °C, which lengthens the heat-up. Use your own reading from the cold tap if you have one.
- A thick factory foam jacket or an insulating jacket on an older cylinder cuts the standing loss, which this calculation does not include.
- Heat pumps and gas combi boilers heat water very differently; for a heat pump cylinder divide the energy by the heat pump's efficiency rather than using 98%.
Sources and further reading
- Energy price cap unit rates and standing charges, Ofgem. GB average electricity unit rate of 26.32p per kWh by Direct Debit, 1 October to 31 December 2026.
- Legionnaires' disease: things to consider, Health and Safety Executive. Store hot water at 60 °C at least; outlets at 50 °C within 1 minute.
- Sanitation, hot water safety and water efficiency: Approved Document G, Ministry of Housing, Communities and Local Government. Statutory guidance on hot water safety in buildings in England.
- University Physics Volume 2, 1.4: Heat Transfer, Specific Heat, and Calorimetry, OpenStax. Q = mcΔT.
Frequently asked questions
How long does a 3 kW immersion heater take to heat a cylinder?
About 2 hours 57 minutes for 150 litres from 10 °C to 60 °C, and about 4 hours 9 minutes for 210 litres. Each litre needs roughly 0.058 kWh for that 50 °C rise.
How much does it cost to run an immersion heater for an hour?
A 3 kW element uses 3 kWh an hour while it is on, so 79p at 26.32p per kWh, the Ofgem cap unit rate for October to December 2026. The thermostat switches it off once the water is hot, so a full heat-up costs the figure in the result, not hours times 79p.
What temperature should a hot water cylinder be set to?
HSE's legionella guidance for those managing water systems advises storing hot water at 60 °C at least, with outlets reaching 50 °C within a minute. To avoid scalds, a thermostatic mixing valve tempers the water at baths and basins.
Is it cheaper to heat water on Economy 7?
Usually, if the off-peak rate is well below your day rate and the cylinder is big enough to last the day. Enter your night rate in the price box to see the cost per heat-up; Ofgem's cap limits the combined cost of multi-rate tariffs, not each rate.
Should I leave the immersion heater on all the time?
With a working thermostat it only draws power when the water cools, but a well insulated cylinder heated once or twice a day at a timed slot usually costs less than keeping it hot around the clock.
Is there an in-depth guide to the Water Heating Time Calculator?
Yes. “How Long Does It Take to Heat Water? Tanks, Kettles and Recovery Rate” covers the background, how it works, common pitfalls and worked examples. Read the full guide.