Australia version. Gas in megajoules, prices in A$, reverse cycle air conditioning as the heat pump, and your state's NGA electricity factor for CO2. US version

Reverse Cycle vs Gas Heating Calculator (Australia)

Compare reverse cycle air conditioning with gas or electric heaters in Australia: gas in MJ from your bill, your tariff in A$ and CO2 on your state's grid factor.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Heat Pump Savings Calculator?

In Australia a heat pump for space heating usually means a reverse cycle air conditioner. Replacing ducted gas or a gas wall heater with one is the common question in Victoria and the ACT, where gas heating is widespread, while in NSW and Queensland it is more often replacing electric panel or bar heaters.

Start from the MJ of gas on your winter bills (subtract the summer baseline for hot water and cooking). The tool works out the heat your home needs from the heater's efficiency, the electricity a reverse cycle unit would use for that heat at its seasonal COP, and both costs.

On emissions the state matters: on Victoria's 0.78 kg per kWh grid factor a reverse cycle system saves money but cuts CO2 only modestly, while rooftop solar or a cleaner grid makes the cut much larger.

  • Gas, oil, propane and electric resistance baselines
  • Heat demand from fuel bills or a known heat load
  • Seasonal COP or HSPF2 input with backup heat share
  • Payback, break-even prices and cost per kWh of heat
  • CO₂e comparison and a COP sensitivity table
Read the guide: Heat Pump vs Gas Furnace: Running Costs and Payback

Updated

How to use the Heat Pump Savings Calculator

  1. Choose your current fuel. Typical defaults for unit, price and efficiency fill in and can be changed.
  2. Enter how much fuel you use for heating a year (winter bills minus summer use for gas) or, if you know it, the heat load in kWh.
  3. Enter the heat pump's seasonal COP, or switch to HSPF2 and enter the rating, plus the share of heat from backup strips.
  4. Enter your electricity price, the installed cost and any rebates, and pick your grid region for CO₂.
  5. Read the yearly costs, saving, payback, break-even prices and the COP sensitivity table.

Worked examples

Ducted gas in Melbourne

Input

40,000 MJ for heating at 4 cents per MJ, 80% efficient heater, reverse cycle at SCOP 4.0, 30 cents per kWh, $9,000 installed

Output

Gas $1,600 a year, reverse cycle $667; saving $933; payback 9.6 years; CO2 2.01 t vs 1.73 t

The house needs 8,889 kWh of heat, which the reverse cycle unit delivers with 2,222 kWh. With solar or cheaper off-peak power at 20 cents the saving rises to $1,156.

Electric panel heaters in Sydney

Input

3,000 kWh of resistance heating at 33 cents, reverse cycle at SCOP 4.0, $4,000 installed

Output

Saving $743 a year; payback 5.4 years

A heat pump uses a quarter of the electricity of resistance heaters for the same heat, so replacing them is usually the fastest payback.

Background and insight

The useful heat delivered by your current system is fuel used x energy per unit x efficiency. Energy contents come from the EIA: a therm is 100,000 Btu (29.31 kWh), a gallon of heating oil 138,500 Btu (40.59 kWh), a gallon of propane 91,452 Btu (26.80 kWh), and natural gas averages 1,036 Btu per cubic foot. Efficiency is the AFUE on the furnace or boiler label: about 80% for a standard gas furnace, 90% to 98% for condensing models, and 100% for electric resistance.

A heat pump moves heat rather than making it, so it delivers more heat than the electricity it uses. The ratio over a heating season is the seasonal coefficient of performance (SCOP). US ratings are given as HSPF2 in Btu of heat per watt-hour of electricity; dividing by 3.412 converts it to an average COP, so HSPF2 8.1 is about 2.4. HSPF2 is calculated for a moderate climate (DOE region IV), and real seasonal COP is lower in very cold places and higher in mild ones. On the coldest days many systems use electric resistance backup strips, which run at COP 1; the backup share setting accounts for that.

Payback is the net installed cost divided by the yearly saving. Federal incentives changed in 2025: the One Big Beautiful Bill Act ended the section 25C energy efficient home improvement credit for property placed in service after 31 December 2025, so the incentives field defaults to zero. Many states and utilities still offer rebates. CO₂ uses EPA Emission Factors Hub 2025 factors for the fuels and your eGRID region's rate for electricity.

Common use cases

  • Deciding on a heat pump

    Get a running-cost answer from your own bills before talking to installers.

  • Replacing an old furnace or boiler

    Compare a like-for-like replacement with switching fuels when the old system fails.

  • Checking an installer's savings claim

    Put the quoted COP and price in and see whether the promised savings hold up.

  • Comparing fuels

    See the cost per kWh of delivered heat for gas, oil, propane and electricity side by side.

Tips and limitations

  • Gas price per MJ: divide the usage charges on your bill by the MJ, and add the daily supply charge only if you will disconnect gas altogether.
  • Use the seasonal efficiency for your climate zone from the Zoned Energy Rating Label, where the model has one, rather than the rated COP; ducted and multi-split systems may not carry it.
  • State schemes such as the Victorian Energy Upgrades program may discount reverse cycle systems that replace gas heaters; enter the discount in incentives.

Sources and further reading

  1. Amendments to National Greenhouse and Energy Reporting legislation, Clean Energy Regulator. State scope 2 factors for 2025-26.
  2. Heating and cooling, energy.gov.au (Australian Government). Reverse cycle units are much more efficient than electric heaters and a preferred replacement for gas heaters.
  3. Understand the Zoned Energy Rating Label, Energy Rating (E3 Program). Seasonal efficiency for hot, average and cold climate zones.

Frequently asked questions

Is reverse cycle cheaper than gas heating?

Compare the cost of a kWh of heat. At 4 cents per MJ and 80% efficiency, gas heat costs 18 cents per kWh; a reverse cycle unit at SCOP 4 and 30 cents per kWh delivers heat at 7.5 cents.

How do I convert my gas bill MJ to kWh?

Divide by 3.6. 40,000 MJ is 11,111 kWh of gas. The tool does this when you choose MJ as the gas unit.

Does reverse cycle heating cut emissions in Victoria?

Yes, modestly at today's grid factor: 1.73 t a year against 2.01 t in the example. Using solar power or a GreenPower plan, and the falling grid factor, increase the saving.

What seasonal COP should I use?

The Zoned Energy Rating Label rates air conditioners for hot, average and cold climate zones (tested for Rockhampton, Richmond and Canberra conditions). Use the manufacturer's seasonal figure for your zone; units score lower in the cold zone.

Should I count the gas supply charge?

Only if you replace every gas appliance and close the account. Then the yearly supply charge becomes a saving to add to the result.

Is there an in-depth guide to the Heat Pump Savings Calculator?

Yes. “Heat Pump vs Gas Furnace: Running Costs and Payback” covers the background, how it works, common pitfalls and worked examples. Read the full guide.