Australia version. Checks a ramp in millimetres against AS 1428.1 as referenced by NCC D4D12: 1:14 maximum, landings every 9 to 15 m, 1,000 mm between handrails and step ramps. US version

Ramp Gradient Calculator (AS 1428.1)

Ramp length, landings and footprint from the rise, checked against AS 1428.1 as the NCC applies it: 1:14 maximum, landings every 9 m and step ramps to 1:10.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Ramp Calculator?

Australian access ramps follow AS 1428.1, which the National Construction Code calls up for ramps on an accessway (NCC Volume One, D4D12). As the Australian Disability Network's Design for Dignity guide summarises the standard (it does not name the edition, so check the edition the NCC calls up), the steepest ramp longer than 1,900 mm is 1:14, gentler than the 1:12 used in the US, and landings are needed at least every 9 m at 1:14 and every 15 m at 1:20, interpolating between. A short step ramp of up to 1,900 mm may be as steep as 1:10 for a rise of up to 190 mm.

Enter the rise in millimetres and the gradient, and the tool splits the ramp into runs between 1,200 mm landings, gives the footprint and handrail length, and checks the 1,000 mm clear width between handrails and the NCC's 3.6 m limit on the rise one ramp may connect. A 600 mm rise at 1:14 is an 8.4 m ramp that just fits without an intermediate landing.

  • ADA 2010 Section 405, existing-site Table 405.2, IRC R311.8 and custom slopes
  • Run, sloped length, angle, percent and number of runs
  • Landings and straight footprint, handrail length per side
  • Pass or fail checks with section numbers
  • Inches or millimetres, copy and share link
Read the guide: ADA Ramp Rules: Slope, Rise, Landings and Handrails

Updated

How to use the Ramp Calculator

  1. Measure the total rise in mm from the path at the bottom to the floor at the top.
  2. Keep the rule on Australia AS 1428.1 (NCC) and enter the gradient as a ratio, for example 14 for 1:14.
  3. Enter the clear width between handrails (1,000 mm minimum).
  4. Leave the landing blank for 1,200 mm, or enter a longer landing where a door opens on to it.
  5. For a small change of level at a doorway, try 1:10 to see whether a step ramp of 1,900 mm or less will do.

Worked examples

Entry ramp, 600 mm rise at 1:14

Input

AS 1428.1, rise 600 mm, 1:14, width 1000 mm

Output

One 8.4 m run; 10.8 m footprint with a 1,200 mm landing at each end

At 1:14 a run may be up to 9 m before a landing is needed, so this ramp needs none in the middle. The gradient is 7.14%, about 4.1 degrees.

A 1.2 m rise at 1:14

Input

AS 1428.1, rise 1200 mm, 1:14, width 1000 mm

Output

Two runs of 8.4 m; 16.8 m of ramp; 20.4 m footprint

One intermediate landing splits the ramp. Folding it into a switchback at that landing usually fits better on a suburban block.

Step ramp at a shopfront, 150 mm at 1:10

Input

AS 1428.1, rise 150 mm, 1:10

Output

1.5 m run; meets the step ramp limits of 1:10, 1,900 mm and 190 mm

Above 190 mm of rise, or beyond 1,900 mm of length, the step ramp no longer applies and the gradient must drop to 1:14.

Background and insight

The rules come from Section 405 of the 2010 ADA Standards. The running slope may not be steeper than 1:12 (405.2) and the cross slope not steeper than 1:48 (405.3). Clear width between handrails is at least 36 inches (405.5). The rise of any single run is 30 inches at most (405.6). Landings at the top and bottom of every run are at least as wide as the ramp and at least 60 inches long, and a landing where the ramp changes direction is at least 60 by 60 inches (405.7). Runs that rise more than 6 inches need handrails on both sides (405.8), mounted 34 to 38 inches high (505.4) and extending 12 inches beyond the top and bottom of the run (505.10).

Existing sites get limited relief under Table 405.2 when space does not allow 1:12: a slope between 1:12 and 1:10 is allowed for a rise of 6 inches at most, and between 1:10 and 1:8 for a rise of 3 inches at most. Nothing steeper than 1:8 is permitted.

Homes follow the International Residential Code where adopted. IRC R311.8 sets a maximum ramp slope of 1:12, allowing 1:8 only where 1:12 is technically infeasible, requires 36 by 36 inch landings at the top and bottom, at doors and at turns, and requires a handrail on at least one side of ramps steeper than 1:12. Many people still build home ramps to ADA dimensions because they are easier to use. Loading ramps for vehicles and equipment are outside these rules; follow the equipment maker's maximum angle.

Common use cases

  • Home access

    Size a ramp for a wheelchair user before buying a modular kit or lumber.

  • Small businesses

    Check an entrance ramp against ADA 405 before a contractor quote or an accessibility review.

  • Thresholds and small changes in level

    Use the existing-site table for short ramps of a few inches where space is tight.

  • Sheds, trailers and loading docks

    Work out the length for a mower, cart or hand truck at any slope.

Tips and limitations

  • A gradient of 1:20 or gentler counts as a walkway rather than a ramp under AS 1428.1, with its own landing rules; at 1:20 the tool keeps landings at most 15 m apart.
  • For a house, NCC Housing Provisions 11.2.3 allows a ramp as steep as 1:8 with landings at least every 15 m; use the custom gradient for that.
  • Many houses are not required by the NCC to have an AS 1428.1 ramp, but building to its gradients and widths makes the ramp usable by a wider range of wheelchairs.

Sources and further reading

  1. NCC Volume One, D4D12 Ramps, Australian Building Codes Board. Ramps on an accessway must comply with AS 1428.1, and a ramp may not connect levels more than 3.6 m apart.
  2. Design for Dignity: ramps, landings and walkways, Australian Disability Network. Summary of AS 1428.1 gradients, landing intervals, 1,000 mm width and step ramps; the page does not name the edition.

Frequently asked questions

What is the maximum ramp gradient in Australia?

1:14 for a ramp longer than 1,900 mm under AS 1428.1, which the NCC applies to ramps on an accessway. Step ramps up to 1,900 mm long can be 1:10 for a rise of up to 190 mm.

How often do you need a landing on a ramp?

At least every 9 m for a 1:14 ramp and every 15 m for a 1:20 ramp, with the spacing for gradients between found by linear interpolation (the tool uses 9 m plus 1 m for each step from 1:14 towards 1:20). Landings are also needed at the top, the bottom and where the ramp turns.

How wide does a wheelchair ramp need to be in Australia?

At least 1,000 mm clear between handrails, kept free of doors, signs and other obstructions.

How long does a ramp need to be for a 450 mm rise?

At 1:14, 450 x 14 = 6,300 mm of horizontal run, which fits in one run under the 9 m limit. Add a 1,200 mm landing at each end and the footprint is 8.7 m.

Is 1:12 allowed in Australia?

Not for an AS 1428.1 ramp longer than 1,900 mm, where 1:14 is the limit. 1:12 is a common US figure and appears on imported ramp kits, so check the gradient before buying one.

Is there an in-depth guide to the Ramp Calculator?

Yes. “ADA Ramp Rules: Slope, Rise, Landings and Handrails” covers the background, how it works, common pitfalls and worked examples. Read the full guide.