Canada version. Adds the CSA S16 clause 13.3.1 factored compressive resistance with φ = 0.90 and the n value for HSS Class C or Class H, reproducing the CISC worked example. US version

Column Buckling Calculator (CSA S16)

Euler load and the CSA S16 factored compressive resistance Cr = φAFy(1 + λ²ⁿ)⁻¹ᐟⁿ for HSS Class C (n = 1.34) and Class H (n = 2.24), checked against CISC tables.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Column Buckling Calculator?

Steel columns in Canada are designed to CSA S16, the CSA standard for steel structures; the British Columbia Building Code, for example, requires structural steel to conform to it in Article 4.3.4.1. Clause 13.3.1 gives the factored compressive resistance as Cr = φ A Fy (1 + λ²ⁿ)⁻¹ᐟⁿ, with φ = 0.90, λ = √(Fy / Fe) and n set by how the section was made. This version sets the design-code check to CSA S16 so the result panel shows λ, n, Cr/A and Cr alongside the Euler load.

The Canadian Institute of Steel Construction publishes a worked example that this calculator reproduces: an HSS 203 x 203 x 6.4 Class C in 350W steel, 4.8 m long, with A = 4,900 mm² and r = 79.9 mm, so KL/r = 60. CISC's Table 4-3 gives Cr/A = 227 MPa and Cr = 1,112 kN; with I and A entered directly the calculator gives 227 MPa and 1,113 kN.

The value of n matters. CISC uses n = 1.34 for hot-rolled shapes and Class C (cold-formed) HSS and n = 2.24 for Class H HSS and welded three-plate members. The same HSS as Class H resists 1,342 kN, 21% more, so check the class on the drawings and the mill certificate.

  • Euler critical load and stress with effective length KL and slenderness KL/r
  • Six end conditions with theoretical and AISC recommended K values, or a custom K
  • Johnson parabola below the transition slenderness, with a clear validity warning
  • AISC 360-16 E3 cross-check with LRFD φPn and ASD Pn/Ω, or a design-code check to BS EN 1993-1-1 (UK NA), IS 800 or CSA S16
  • Tube, bar, SHS and rectangle sections or your own I and A, SI and US units, column curve chart
Read the guide: Column Buckling Explained: Euler, K Factors, Slenderness and the Johnson Parabola

Updated

How to use the Column Buckling Calculator

  1. Choose SI or US units, then pick the end conditions. The list shows the theoretical K and the AISC recommended design K for each.
  2. Select whether to use the design value, the theoretical value or a custom K, and enter the unbraced length L between lateral supports.
  3. Pick a material to fill in E and the yield strength, or type your own. Leave Fy blank for a pure Euler result.
  4. Describe the cross-section. For an I-beam or channel, enter the weak-axis I and the area from a section table, because the column buckles about the axis with the smallest I.
  5. Read the Euler load, slenderness, governing formula and allowable load, and check the AISC E3 values and the column curve.

Worked examples

CISC example: HSS 203 x 203 x 6.4 Class C, 4.8 m

Input

Enter I and A directly: I 3,128 cm⁴, A 49.0 cm²; K = 1.0; Fy 350 MPa; E 200 GPa; CSA S16, cold-formed

Output

KL/r 60.1; λ 0.80; n 1.34; Cr/A 227 MPa; Cr 1,113 kN

I is A r² from the CISC figures (4,900 mm² x 79.9² mm²). Euler gives 2,680 kN, so the code resistance is well under half the elastic load.

Same column as HSS Class H

Input

As above, section type hot-finished

Output

n 2.24; Cr/A 274 MPa; Cr 1,342 kN

At 6.0 m the Class C column drops to 920 kN and the Class H one to 1,133 kN.

Background and insight

Leonhard Euler derived the critical load of an ideal pin-ended column in 1744: Pcr = π²EI/L². Other end conditions are handled by replacing L with an effective length KL, the distance between points of zero moment in the buckled shape. A column fixed at both ends buckles like a pinned column half as long (K = 0.5), a flagpole fixed at the base and free at the top like one twice as long (K = 2.0). Since the load varies with 1/K², end fixity changes capacity by a factor of up to sixteen.

Euler assumes the material stays elastic, so it is only valid when the critical stress Pcr/A is below the proportional limit. Real rolled and welded sections carry residual stresses from cooling, so yielding starts earlier; the classic structural stability texts (and the old AISC allowable stress method) put the limit at half the yield stress. Below the transition slenderness Cc = √(2π²E/Fy), J. B. Johnson's parabola, σcr = Fy − (Fy²/4π²E)(KL/r)², joins the Euler curve tangentially at Fy/2 and caps the stress at Fy for a stub column.

Modern steel codes use a single curve fitted to tests on columns with real out-of-straightness. AISC 360-16 Section E3 gives Fcr = 0.658^(Fy/Fe) Fy for KL/r up to 4.71√(E/Fy) and 0.877 Fe beyond, where Fe is the Euler stress, with φ = 0.90 for LRFD and Ω = 1.67 for ASD. The recommended K values (0.65, 0.80, 1.2, 1.0, 2.1 and 2.0) come from Commentary Table C-A-7.1.

Common use cases

  • Posts and pipe columns

    Check a steel post, lally column or tube upright under a beam before choosing its size.

  • Struts, braces and push rods

    Find the buckling load of a compression strut, linkage, actuator rod or truss member.

  • Machine and frame design

    Size aluminium or steel frame legs and slender machine parts against elastic buckling.

  • Teaching stability

    Show how K, length and section shape move a column along the Euler and Johnson curves.

Tips and limitations

  • Use the actual HSS area and radius of gyration from the CISC handbook in the custom mode; the shape mode uses sharp corners and overstates the area slightly.
  • CISC's Cr/A tables (4-3 and 4-4) run up to KL/r = 200; check the S16 slenderness limit for your member.
  • For W-shapes, use the minor-axis radius of gyration unless the weak axis is braced.

Sources and further reading

  1. A useful engineering tool to quickly calculate the compressive resistance of compression members, Canadian Institute of Steel Construction. Tables 4-3 (n = 1.34) and 4-4 (n = 2.24) to CSA S16 clause 13.3.1; worked example HSS 203 x 203 x 6.4, Cr = 1,112 kN.
  2. National Building Code of Canada, National Research Council Canada (Government of Canada Publications). Part 4, structural design.
  3. British Columbia Building Code 2018, Division B, Section 4.3: Design requirements for structural materials, Province of British Columbia. Article 4.3.4.1: buildings and structural members of structural steel shall conform to CSA S16.

Frequently asked questions

What is the CSA S16 formula for compressive resistance?

Cr = φ A Fy (1 + λ²ⁿ)⁻¹ᐟⁿ, with φ = 0.90, λ = √(Fy / Fe), Fe = π²E / (KL/r)² and n = 1.34 or 2.24 depending on the section. The calculator shows each term.

When do I use n = 2.24 instead of 1.34?

CISC applies n = 2.24 (Table 4-4) to HSS made to CSA G40.21 Class H and to welded three-plate members with flame-cut flange edges; hot-rolled shapes and Class C HSS use n = 1.34 (Table 4-3).

What is the unit factored resistance Cr/A?

The compressive resistance per unit area, in MPa. CISC tabulates it against KL/r and Fy so designers can multiply by A; for 350 MPa, Class C and KL/r 60 it is 227 MPa.

Which steel grade should I use for HSS in Canada?

CSA G40.21 350W is the common grade for Class C HSS, with Fy = 350 MPa; ASTM A500 and A1085 sections are also used. Enter the yield strength of the grade you specify.

Why is the Euler load so much higher than Cr?

Euler assumes a perfectly straight, centrally loaded column without residual stresses. The S16 formula covers real columns, and φ = 0.90 adds the resistance factor.

Is there an in-depth guide to the Column Buckling Calculator?

Yes. “Column Buckling Explained: Euler, K Factors, Slenderness and the Johnson Parabola” covers the background, how it works, common pitfalls and worked examples. Read the full guide.