Canada version. Feet and inches as Canadian yards sell lumber, 2x6 exterior walls at 16 or 24 in, 92-5/8 in precuts, OSB sheathing and a pointer to Part 9 of the National Building Code. US version
Wall Framing Calculator (Canada)
Count 2x6 or 2x4 studs, plates and headers for a Canadian wall at 16 or 24 in on centre, with windows, doors, OSB sheathing and the 38 x 89 and 38 x 140 mm sizes.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Wall Framing Calculator?
Canadian houses are framed with the same nominal lumber as in the US, but the sizes are written both ways: a 2x4 is 38 x 89 mm and a 2x6 is 38 x 140 mm. 2x6 exterior walls are common because they leave a deeper cavity for the batt insulation the energy requirements call for, while interior partitions are often 2x4.
This version starts with a 20 ft 2x6 exterior wall, 8 ft high with 92-5/8 in precut studs, two windows with triple 2x10 headers, two corners and one partition junction. At 16 in on centre that is 33 studs with 10% extra; at 24 in on centre it is 28, which is why 24 in framing appears in many energy-focused builds.
Stud size and spacing, headers, top plates and nailing for houses come from Part 9 of the National Building Code of Canada, as adopted by your province. Check the edition in force where you build, since provinces adopt and amend it on their own timetables.
- Feet-inch-fraction or metric input with live echo of the parsed value
- Layout studs, opening deductions, kings, jacks and cripples
- Corner and intersection studs set to your framing style
- Plate linear feet and stock pieces, header lengths, sheathing sheets
- Itemised stud table, copy and share link
Updated
How to use the Wall Framing Calculator
- Pick imperial or metric and enter the wall length and the height to the top of the plates.
- Choose the stud spacing, the stud thickness, and single or double top plate.
- Enter the number of corners and wall intersections and the extra studs each one uses in your framing style.
- Enter doors and windows by rough opening width and height, the window sill height, header depth, plies and jack studs per side.
- Read the studs to buy, stud length, plates, headers and sheathing, and check the table showing where the studs go.
Worked examples
20 ft exterior 2x6 wall at 16 in on centre
Input
20 ft x 97-1/8 in, 2x6 at 16 in, double top plate, 2 corners and 1 junction (2 extra studs each), two 48 x 44 in windows at a 36-1/2 in sill, 2x10 headers of 3 plies, 10% extra
Output
33 studs to buy (30 net) at 92-5/8 in; 60 lf of plate (6 pieces of 16 ft); 6 header pieces at 51 in; 6 sheets of 4 x 8 sheathing
Each window takes two king studs, two jacks and three short studs above and below. Three plies make a 2x10 header the full width of a 2x6 wall.
The same wall at 24 in on centre
Input
As above, studs at 24 in
Output
28 studs to buy (25 net)
Five fewer studs and less thermal bridging, provided the stud tables and the sheathing allow 24 in for the load the wall carries.
9 ft basement or main-floor wall with a door
Input
14 ft x 109-1/8 in, 2x4 at 16 in, double top plate, 2 corners and 1 partition junction (2 extra studs each), one 38 x 82-1/2 in rough opening, no windows, 2-ply 2x10 header, 10% extra
Output
25 studs to buy (22 net) at 104-5/8 in; 42 lf of plate; 2 header pieces at 41 in; 5 sheets
Nine-foot walls use 104-5/8 in precuts. Basement walls that sit on concrete need a sill plate separated from the slab.
Background and insight
Studs are laid out from one end of the wall at a fixed spacing, so a wall of length L holds ceil(L / s) + 1 studs including the one at the far end: ten studs for a 12 ft wall at 16 in. Sixteen-inch layout lines up with 4 ft sheets every third stud; 24 in layout, used in advanced framing, lines up every second stud and saves roughly a third of the studs. Metric frames use 400 or 600 mm for the same reason with 1200 mm sheets.
A standard 8 ft wall is 97-1/8 in from floor to the top of the double top plate: three plates at 1-1/2 in plus a 92-5/8 in precut stud. That leaves room for a 96 in sheet of drywall on the wall plus the thickness of the ceiling board. Each opening gets a king stud on both sides running full height and one or more jack (trimmer) studs carrying the header; short cripples fill the layout above the header and below a window sill. Header size depends on the opening width and the load above and comes from a header span table such as IRC Table R602.7(1).
Common use cases
Ordering lumber for a room addition
Total studs, plates and headers wall by wall before calling the yard.
Basement and garage partitions
Count studs for non-bearing walls with a single top plate or 24 in spacing.
Bidding framing labour
Use the stud and opening counts as the basis for a per-piece or per-opening price.
Learning wall anatomy
See how kings, jacks, cripples and corner studs add up and where the extra studs go.
Tips and limitations
- Order exterior wall studs as 2x6 precuts and partitions as 2x4; keep them in separate piles on site so the sizes do not get mixed.
- Add blocking for kitchen cabinets, grab bars and handrails while the wall is open; the calculator does not count it.
- Plan the air barrier and vapour barrier details at headers and rim joists before you sheathe, as these are where leaks show up in a blower-door test.
Sources and further reading
- National Building Code of Canada 2025, National Research Council Canada (Government of Canada Publications). Part 9 covers wood-frame construction of houses and small buildings.
- Lumber, Canadian Wood Council. Nominal and metric sizes such as 38 x 89 mm for a 2x4.
Frequently asked questions
Are exterior walls in Canada framed with 2x6 or 2x4?
2x6 (38 x 140 mm) exterior walls are common because the cavity holds more batt insulation, and some builds add exterior insulation as well. Interior partitions are often 2x4 (38 x 89 mm). The National Building Code sets the minimum stud sizes; energy requirements usually decide the depth.
Can I frame walls at 24 inches on centre in Canada?
Often, for walls that meet the stud size and spacing limits in Part 9 of the National Building Code for the load they carry, with sheathing and cladding rated for 24 in. Check the table in the code edition your province has adopted before you change the layout.
What length are precut studs in Canada?
92-5/8 in for an 8 ft wall with a single bottom plate and a double top plate, and 104-5/8 in for a 9 ft wall. The calculator works the stud length out from the wall height and the number of plates.
How many plies does a header need in a 2x6 wall?
Three 2x plies, or two plies with a spacer or rigid insulation, make up the 5-1/2 in wall thickness. The header depth comes from the header span table for the opening width and the load above; enter the depth and plies you are using.
How do I convert 2x4 and 2x6 to metric?
Canadian lumber is graded and sized to the same standard as US lumber: a 2x4 is 38 x 89 mm and a 2x6 is 38 x 140 mm actual. Switch the calculator to metric if your drawings are in millimetres.
Is there an in-depth guide to the Wall Framing Calculator?
Yes. “How Many Studs Do I Need? Wall Framing Takeoffs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like
Free, in-browser tools that pair well with this one.