Canada version. Checks a ramp in millimetres against Canadian provincial codes based on the National Building Code: barrier-free ramps at 1 in 12, and Part 9 ramps serving a house. US version

Wheelchair Ramp Calculator (Canada, Ontario Rules)

Ramp length, runs and landings in millimetres for a barrier-free ramp at 1 in 12 with a landing every 9 m, or a Part 9 ramp to a house at up to 1 in 10.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Ramp Calculator?

Building codes in Canada are provincial, but most follow the National Building Code, and a barrier-free ramp is generally no steeper than 1 in 12, with a level landing at least every 9 m of ramp and handrails on both sides. The figures in this tool are Ontario's, from the Ontario Building Code 2012 as summarized by Kitchener and North Bay: 900 mm between handrails, 1,670 x 1,670 mm level areas at the top and bottom, and handrails 865 to 965 mm high that extend 300 mm past each end. Ontario's 2024 code took effect on 1 January 2025, so check its text before you build. Curb heights, intermediate landing sizes and handrail extensions differ by province (Ontario: 50 mm curb and 1,670 mm landings; Manitoba: 75 mm curb and 1.35 m intermediate landings), and Manitoba's code, based on the 2020 NBC, asks for 1,000 mm between handrails.

A ramp that only serves your own house is usually a Part 9 ramp instead, which under the Ontario 2012 code may be as steep as 1 in 10 outdoors, at least 860 mm wide, with no more than 1,500 mm of rise between landings when it is steeper than 1 in 12. Pick the rule, enter the rise from grade to the door sill in millimetres and the slope, and the tool works out the runs, landings, footprint and handrail length.

  • ADA 2010 Section 405, existing-site Table 405.2, IRC R311.8 and custom slopes
  • Run, sloped length, angle, percent and number of runs
  • Landings and straight footprint, handrail length per side
  • Pass or fail checks with section numbers
  • Inches or millimetres, copy and share link
Read the guide: ADA Ramp Rules: Slope, Rise, Landings and Handrails

Updated

How to use the Ramp Calculator

  1. Choose "Canada barrier-free ramp" for public buildings, apartment entrances and workplaces, or "Canada Part 9 ramp to a house" for a private home.
  2. Enter the total rise in mm, from the ground at the bottom to the top of the door sill.
  3. Enter the slope as a ratio (12 for 1 in 12), a percentage or an angle.
  4. Enter the clear width between handrails.
  5. Leave the landing blank to use Ontario's 1,670 mm, or enter your province's landing size; outside Ontario, check your provincial code for each figure.

Worked examples

Barrier-free entrance, 600 mm rise at 1 in 12

Input

Canada barrier-free ramp, rise 600 mm, 1 in 12, width 1000 mm

Output

One 7.2 m run; 10.54 m footprint with 1,670 mm level areas at both ends

A 7.2 m run is within the 9 m limit, so no intermediate landing is needed. The 1,000 mm width meets Manitoba's figure as well as Ontario's 900 mm.

Barrier-free ramp, 900 mm rise

Input

Canada barrier-free ramp, rise 900 mm, 1 in 12, width 900 mm

Output

Two runs of 5.4 m; 10.8 m of ramp; 15.81 m footprint with three landings

At 1 in 12 a 900 mm rise needs 10.8 m of ramp, more than 9 m, so it is split with a level landing. Turning the ramp at that landing fits it alongside the building.

Ramp to a house, 600 mm rise at 1 in 10

Input

Canada Part 9 ramp to a house, rise 600 mm, 1 in 10, width 900 mm

Output

One 6 m run, 5.71 degrees; footprint 6 m before landings

Part 9 allows 1 in 10 outdoors, but a wheelchair user pushing alone may find 1 in 12 or gentler much easier. The rise is under the 1,500 mm limit between landings.

Background and insight

The rules come from Section 405 of the 2010 ADA Standards. The running slope may not be steeper than 1:12 (405.2) and the cross slope not steeper than 1:48 (405.3). Clear width between handrails is at least 36 inches (405.5). The rise of any single run is 30 inches at most (405.6). Landings at the top and bottom of every run are at least as wide as the ramp and at least 60 inches long, and a landing where the ramp changes direction is at least 60 by 60 inches (405.7). Runs that rise more than 6 inches need handrails on both sides (405.8), mounted 34 to 38 inches high (505.4) and extending 12 inches beyond the top and bottom of the run (505.10).

Existing sites get limited relief under Table 405.2 when space does not allow 1:12: a slope between 1:12 and 1:10 is allowed for a rise of 6 inches at most, and between 1:10 and 1:8 for a rise of 3 inches at most. Nothing steeper than 1:8 is permitted.

Homes follow the International Residential Code where adopted. IRC R311.8 sets a maximum ramp slope of 1:12, allowing 1:8 only where 1:12 is technically infeasible, requires 36 by 36 inch landings at the top and bottom, at doors and at turns, and requires a handrail on at least one side of ramps steeper than 1:12. Many people still build home ramps to ADA dimensions because they are easier to use. Loading ramps for vehicles and equipment are outside these rules; follow the equipment maker's maximum angle.

Common use cases

  • Home access

    Size a ramp for a wheelchair user before buying a modular kit or lumber.

  • Small businesses

    Check an entrance ramp against ADA 405 before a contractor quote or an accessibility review.

  • Thresholds and small changes in level

    Use the existing-site table for short ramps of a few inches where space is tight.

  • Sheds, trailers and loading docks

    Work out the length for a mower, cart or hand truck at any slope.

Tips and limitations

  • A ramp is a structure: many municipalities require a building permit, and a deck-style ramp needs footings below frost depth.
  • Snow and ice make a ramp unusable; plan where the snow will go and consider a roof or a heated surface.
  • Accessibility programs in some provinces help pay for home ramps; check your provincial housing agency.

Sources and further reading

  1. Barrier-free ramp standard detail (Ontario Building Code 2012, Division B, 3.8.3.4), City of Kitchener. Ontario barrier-free ramp width, slope, landings, handrails and curbs.
  2. Ramps: a guide to the building code requirements for commercial barrier-free ramps, City of Winnipeg. Manitoba Building Code 2024 (based on the 2020 NBC) requirements, including the 75 mm curb and 1.35 m intermediate landings.
  3. Private ramps for residences (Ontario Building Code 2012, 9.8.5), City of North Bay. Part 9 ramp width, slope and maximum rise.
  4. National Building Code of Canada 2025, National Research Council of Canada (Government of Canada Publications)

Frequently asked questions

What is the maximum slope for a wheelchair ramp in Canada?

1 in 12 (8.33%, about 4.8 degrees) for a ramp in a barrier-free path of travel. A ramp serving only a single house is governed by Part 9 and may be up to 1 in 10 outdoors, but 1 in 12 is easier to use.

How often does a ramp need a landing in Canada?

Barrier-free ramps need a level landing at least every 9 m along the ramp, at every change of direction of 90 degrees or more, and at the top and bottom. Sizes differ by province: in Ontario (2012 code) the level areas are 1,670 x 1,670 mm, while Manitoba allows 1.35 x 1 m intermediate landings.

How wide does a wheelchair ramp need to be?

The Ontario Building Code 2012 requires at least 900 mm between handrails for a barrier-free ramp, and Manitoba's 2024 code (based on the 2020 NBC) 1,000 mm. Under the Ontario 2012 code a Part 9 ramp serving one dwelling must be at least 860 mm wide. Check the current edition of your provincial code.

How high should ramp handrails be?

Under the Ontario Building Code 2012, between 865 and 965 mm above the ramp surface, on both sides, extending at least 300 mm horizontally past the top and bottom, and graspable along their whole length. Extensions differ in other provinces.

How long is a ramp for three steps?

Three 180 mm steps are a 540 mm rise. At 1 in 12 that needs 6.48 m of horizontal run, plus a landing at each end; at 1 in 10 it is 5.4 m.

Is there an in-depth guide to the Ramp Calculator?

Yes. “ADA Ramp Rules: Slope, Rise, Landings and Handrails” covers the background, how it works, common pitfalls and worked examples. Read the full guide.