United Kingdom version. UK pitched roofs: degrees, metres, and tiles or slates counted from the batten gauge and cover width, with battens in metres instead of US shingle bundles. US version

Roof Tile and Slate Calculator (UK)

Roof area in m² from the footprint and pitch in degrees, then plain tiles, interlocking tiles or slates per m² from gauge and cover width, plus battens in metres.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Roofing Calculator?

UK roofs are covered in clay or concrete tiles and natural or man-made slates, hung on timber battens. How many you need depends on two numbers: the batten gauge (the spacing up the slope) and the cover width of each unit across the roof. Tiles per m² is simply 1,000,000 divided by gauge times cover width in millimetres.

For a plain clay tile 265 x 165 mm laid at a 100 mm gauge, that is 60.6 tiles per m². A 500 x 250 mm slate at a 75 mm headlap has a gauge of (500 minus 75) divided by 2, so 212.5 mm, and with a 5 mm gap a cover width of 255 mm: 18.45 slates per m². Interlocking concrete tiles cover far more per tile, so check the maker's data sheet for the gauge and cover width of the tile you are pricing.

Enter the house footprint, the overhang at eaves and verges, and the pitch in degrees. The tool gives the sloping roof area in m², the number of tiles or slates with waste, the batten length and the ridge and hip length for ridge tiles.

  • Gable, hip and shed roofs from footprint, overhang and pitch
  • Pitch as rise in 12 or degrees, with a multiplier table
  • Squares, bundles, underlayment rolls, ridge cap and drip edge in one result
  • Editable bundles per square, roll coverage, cap coverage and piece length
  • Imperial or metric inputs, cost per bundle, copy and share
Read the guide: Roof Pitch, Stair Layout, AC Sizing and Running Costs Explained

Updated

How to use the Roofing Calculator

  1. Set units to metric and pitch to degrees; UK roof pitches are quoted in degrees.
  2. Enter the footprint length along the ridge, the width, and the overhang on each side.
  3. Pick "Tiles or slates (batten gauge)" and enter the gauge and cover width from the tile maker's data, or work them out for slates and plain tiles.
  4. Add 10% for a simple gable, more for hips, valleys and dormers where tiles are cut.

Worked examples

Plain clay tiles on a gable roof

Input

9 x 7.5 m footprint, 0.3 m overhang, 40°, gable, 100 mm gauge, 165 mm cover, 10% waste

Output

101.5 m² of roof; 60.61 tiles per m²; 6,768 tiles; 1,116.6 m of batten

Plain tiles are double-lapped, so they need many more units and battens than interlocking tiles. Steep pitches suit them, which is why the example uses 40°.

Natural slate on the same house at 35°

Input

500 x 250 mm slates, 75 mm headlap (gauge 212.5 mm), 255 mm cover, 10% waste

Output

94.9 m²; 18.45 slates per m²; 1,928 slates; 491.4 m of batten

Headlap is set by pitch and exposure; a lower pitch or a more exposed site needs a bigger lap, which shortens the gauge and raises the count.

Interlocking concrete tiles

Input

Same 35° roof, 343 mm gauge, 300 mm cover width, 10% waste

Output

9.72 tiles per m²; 1,015 tiles; 304.4 m of batten

Gauge and cover width here are example values. Every interlocking tile has its own published maximum gauge and cover width, so take both from the product sheet.

Background and insight

The pitch multiplier is the length of a rafter per unit of horizontal run: the square root of 1 + (rise / 12)². At 6 in 12 it is 1.118, so a roof covers 11.8% more surface than its footprint; at 12 in 12 (45°) it is 1.414. Because every plane of a simple gable or hip roof has the same pitch, multiplying the total plan area by this one factor gives the whole roof area, however the planes are arranged.

Asphalt shingles are sold so that three bundles cover one square for most three-tab and many architectural products, but heavier laminated shingles can need four or five, which is why the wrapper is the final word. Nominal underlayment coverage is about 400 ft² for a roll of #15 felt, 200 ft² for #30 and around 1,000 ft² for many synthetic rolls, less once laps are taken out.

Hips and valleys need cut shingles along their full length, and dormers add both. A plain gable is often estimated at 10% waste and a cut-up hip roof at 15% or more, which is a judgment call rather than a formula.

Common use cases

  • Checking a reroof quote

    Compare the number of squares on a contractor quote with an independent figure from the footprint and pitch.

  • Ordering shingles for a shed or garage

    Get bundles, underlayment and drip edge for a small DIY roof in one pass.

  • Estimating before a storm claim

    Know the approximate roof area before an adjuster visits, so the numbers in the claim make sense to you.

  • Comparing pitch options on new builds

    See how moving from 4/12 to 8/12 changes material quantities and the edge lengths.

Tips and limitations

  • BS 5534 is the code of practice for slating and tiling; manufacturers publish fixing specifications to it for each tile and pitch.
  • Switching from slate to concrete tiles, or the reverse, changes the load on the rafters, which can need a structural check.
  • Re-covering a roof is treated as renovating a thermal element, so insulation may need upgrading at the same time.

Sources and further reading

  1. Building regulations: re-roofing, Planning Portal. Thermal upgrade when re-covering, and structural checks for heavier or lighter coverings.
  2. BS 5534 Slating and tiling for pitched roofs and vertical cladding. Code of practice, BSI
  3. Working at height, Health and Safety Executive

Frequently asked questions

How many roof tiles do I need per square metre?

Divide 1,000,000 by the batten gauge times the cover width, both in mm. Plain tiles at a 100 mm gauge and 165 mm cover need about 60.6 per m²; interlocking tiles need far fewer, set by the gauge and cover width on the maker's data sheet; slates of 500 x 250 mm need about 18 to 19.

How do I work out the batten gauge for slates?

For double-lapped slates and plain tiles, gauge = (length of slate minus headlap) divided by 2. A 500 mm slate with a 75 mm headlap gives 212.5 mm. Interlocking tiles use the maker's stated gauge range instead.

Do I need building regulations approval to re-roof my house?

Often yes. The Planning Portal says a roof is a thermal element, so re-covering it should include improving insulation, and a covering that is much heavier or lighter than the old one may need the structure checking. Ask your council building control or use a registered competent roofer.

How many metres of batten do I need?

One batten line runs across the roof at every gauge up the slope, so the length is about roof area divided by gauge in metres. A 94.9 m² roof at 212.5 mm gauge needs about 447 m, or 491 m with 10% for offcuts.

What is the minimum pitch for roof tiles in the UK?

It depends on the tile. Plain tiles are generally laid at steep pitches, while some interlocking concrete tiles are rated for much lower pitches. The maker states the minimum for each product, and BS 5534 covers the details.

Is there an in-depth guide to the Roofing Calculator?

Yes. “Roof Pitch, Stair Layout, AC Sizing and Running Costs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.