Balustrade Spacing in NZ: The 100 mm Rule and F4/AS1

How many balusters fit a deck or stair bay in New Zealand with equal gaps under the F4/AS1 100 mm sphere, the 150 mm stair triangle and no climbable rails.

By · · 9 min read

Illustration for the Baluster Spacing Calculator guide

New Zealand edition. Written for New Zealand decks and stairs: Building Code clause F4 and Acceptable Solution F4/AS1 (100 mm sphere, non-climbable barriers, 150 mm stair triangle), D1/AS1 stair limits from BRANZ, the 1.5 m consent exemption and millimetres throughout. US edition

In New Zealand the gaps in a deck or stair balustrade in a home must not let a 100 mm sphere through, and the barrier must not be climbable. Work out how many balusters you need first, then share the leftover space so every gap is equal and under 100 mm. On a 2,100 mm deck bay with 42 mm balusters that is 15 balusters with 91.9 mm gaps at 133.9 mm centres. The Baluster Spacing Calculator (NZ) does the sums, including the marks along a raked stair; this guide explains the rules behind the numbers and where layouts go wrong.

When a deck or stair needs a barrier

Building Code clause F4, Safety from falling, requires a barrier wherever people could fall 1 metre or more (Building CodeHub). Measure the drop at the edge you are guarding, down to the ground beneath. A deck that is 700 mm above the lawn by the house can be well over a metre at the outer edge of a sloping section.

Consent is a separate question. Exemption 24 in Schedule 1 of the Building Act lets you build a deck or platform without building consent as long as it is not possible to fall more than 1.5 metres from it, but, as the LBP Codewords series points out, the work must still meet the Building Code, so a deck with a 1.2 m drop needs a compliant barrier even though it needs no consent.

What F4/AS1 asks of the infill

Acceptable Solution F4/AS1 is the usual way to show a barrier complies. BRANZ Bulletin 625 (August 2018) summarises its requirements for barriers in areas frequented by children under 6:

WhatRequirement
Openings in the barriera 100 mm diameter sphere cannot pass through
Climbabilitynot climbable: generally no horizontal rails
Stair trianglethe opening between tread, riser and bottom rail must not pass a 150 mm sphere

BRANZ treats stairs within a dwelling as the typical case of children under 6 being about, so for a family home plan on the 100 mm rule everywhere. Two consequences catch people who use Australian or American plans:

  • The sphere is smaller. Australia's NCC uses 125 mm and the US code 4 inches (about 102 mm). A layout drawn to 125 mm fails here.
  • Horizontal infill is out. Horizontal slats, rails or wires in a barrier children use make it climbable. Vertical balusters are the simple way to meet F4/AS1; anything else needs a designer and a conversation with the council.

BRANZ also notes there is no Acceptable Solution for the structural design of safety barriers, so posts, fixings and glass generally need specific design. The calculator handles the spacing; the barrier height and the post and rail sizes come from F4/AS1 and your designer.

Counting balusters for a deck bay

With n balusters of width b in a clear length L between post faces, there are n + 1 gaps, one at each post:

n = ceil( (L - g) / (b + g) )
gap = (L - n x b) / (n + 1)

For a 2,100 mm bay with 42 mm balusters and a 100 mm limit: (2,100 - 100) / (42 + 100) = 14.08, which rounds up to 15. Each gap is (2,100 - 15 x 42) / 16 = 91.9 mm.

A deck bay between two posts with 15 blue balusters spaced evenly and a red circle for the 100 mm sphere of F4/AS1. The working shows n = ceil(2,000 / 142) = 15, gap = 1,470 / 16 = 91.9 mm, centres 133.9 mm apart and the first centre 112.9 mm from the post. An inset shows that on a stair the gap is measured level between vertical balusters, and the tread triangle must stop a 150 mm sphere.
A deck bay between two posts with 15 blue balusters spaced evenly and a red circle for the 100 mm sphere of F4/AS1. The working shows n = ceil(2,000 / 142) = 15, gap = 1,470 / 16 = 91.9 mm, centres 133.9 mm apart and the first centre 112.9 mm from the post. An inset shows that on a stair the gap is measured level between vertical balusters, and the tread triangle must stop a 150 mm sphere.

The 14.08 is worth noticing: fourteen balusters would have left gaps just over 100 mm, so the fifteenth brings them down to 91.9 mm with an 8.1 mm margin. That margin is the same if you set a stricter 95 mm working limit, so a 2,100 mm bay needs no extra baluster to build in some tolerance. Set the first centre one gap plus half a baluster from the post (91.9 + 21 = 112.9 mm), then every 133.9 mm. A deck with four identical bays takes 60 balusters.

How the count changes with the infill on the same 2,100 mm bay:

InfillLimitCountGap
42 mm timber balusters100 mm (F4/AS1)1591.9 mm
32 mm aluminium balusters100 mm1693.4 mm
65 mm blades100 mm1389.6 mm
42 mm timber balusters125 mm (an Australian plan)12122.8 mm, fails F4/AS1

Measure turned or tapered balusters at their narrowest point, because that is where the widest gap sits.

Stair barriers: measure level, mark along the rail

On a stair the balusters stand vertical and the rail slopes, so the sphere passes level between two balusters. The calculator converts the length along the rail to a level run, spaces the balusters on the level and converts the centres back to marks along the rail:

level run = length along the rail x cos(stair angle)
centres along the rail = level centres / cos(stair angle)

BRANZ's summary of D1/AS1 gives a common or main private stair a maximum riser of 190 mm, a minimum tread of 280 mm and a maximum pitch of 37°, and a secondary private stair 200 mm, 250 mm and 41°. It also says the old rule of thumb of two risers plus one tread should not be used. A main stair at the limits, 190 mm risers and 280 mm treads, rakes at 34.2°. For a barrier 3,000 mm long along the rail:

100 mm limit95 mm working limit
Level run2,482.4 mm2,482.4 mm
Balusters1718
Level gap98.2 mm90.9 mm
Centres along the rail169.5 mm160.6 mm
First centre along the rail144.1 mm135.2 mm

At 100 mm the gaps pass by only 1.8 mm. A working limit of 95 mm adds one baluster and buys a 9.1 mm margin, which is cheap insurance against timber that twists after fixing.

Then check the bottom of the barrier. At each tread, the triangle formed by the tread, the riser and the bottom rail must stop a 150 mm sphere. The calculator does not check this; hold a 150 mm disc or offcut in the gap before the bottom rail is fixed.

Mark running totals, not repeated steps

Round the 169.5 mm centres down to 169 and step them off sixteen times, and each step loses 0.5 mm along the rail. By the last baluster the error is 7.8 mm along the rail, and the last level gap grows from 98.2 mm to 104.7 mm, which fails the 100 mm rule on a layout that was right on paper. Hook the tape on the newel and mark every centre at its running total (144.1, 313.6, 483.1, 652.6 mm and so on, as the calculator's layout table lists), or make a story stick once and reuse it.

Who checks it, and what this guide leaves out

For consented work the council checks the barrier against the Building Code. For exempt work, you or your builder are responsible for meeting it anyway. Pool barriers are a different regime under the Building Act and are not covered here, and the strength of posts, fixings and glass is a design question.

Tools for this job

The US edition of this guide explains the 4 inch rule used on American plans.

Frequently asked questions

What is the maximum gap between balusters in NZ?

Where children under 6 are about, which BRANZ treats as the normal case for stairs in a home, F4/AS1 says a 100 mm sphere must not pass through any opening. Design to 95 mm or less so timber movement does not push a gap over.

Does my deck need a balustrade?

Clause F4 requires a barrier where people could fall 1 metre or more. Check every edge, because on a sloping section part of a deck can exceed 1 m even when the end by the house does not.

Can I build a deck without consent in NZ?

Exemption 24 allows a deck or platform without building consent if it is not possible to fall more than 1.5 metres from it. The barrier is still needed wherever the fall is 1 metre or more.

Are horizontal balustrades allowed in NZ homes?

Not where children under 6 are about. F4/AS1 expects those barriers not to be climbable, which generally means no horizontal rails. Use vertical balusters or get a designer involved.

Sources and further reading

Open the Baluster Spacing Calculator

More Carpentry & Woodworking

Every tool in the Carpentry & Woodworking section, free and in your browser.