How Many Plasterboard Sheets Do I Need for a Room?

Counting plasterboard sheets from 2400 to 6000 mm for Australian walls and ceilings, screws, tape and base coat, sheet weights, wet-area board and asbestos checks.

By · · 9 min read

Illustration for the Drywall Calculator guide

Australia edition. Australian plasterboard as Gyprock sells it, 1200 mm sheets from 2400 to 6000 mm long, horizontal sheeting, sheet weights from SafeWork SA and Gyprock data, wet-area board, prices in A$ and SafeWork NSW asbestos advice. US edition

A 3.6 by 3.4 metre bedroom with a 2.4 metre ceiling, a door and a 1810 mm window has 42 m² of wall and ceiling to sheet. That is 17 sheets of 1200 x 2400 mm plasterboard with 10% for cuts, or 11 sheets of 1200 x 3600 mm hung horizontally, with fewer joints to set. The Plasterboard Calculator (Australia) gives the count, screws, tape and compound for your room in metres and A$; this guide explains each figure and what is specific to sheeting an Australian house.

Sheet sizes you can buy

Australian plasterboard comes 1200 mm wide (some products also in 900 or 1350 mm) in a long run of lengths. Gyprock Plus, a 10 mm board for walls and ceilings, is listed from 2400 to 6000 mm, typically in 300 mm steps, with 2400, 2700, 3000, 3600, 4200, 4800, 5400 and 6000 mm as product options. Stockholdings vary by state, so ask your supplier which lengths are on the shelf.

Long lengths let you hang walls horizontally. Two 1200 mm sheets stacked on edge cover a 2.4 m wall exactly, and a sheet as long as the wall leaves no butt joint in the middle, the hardest joint to set flat.

The bedroom, step by step

  • Walls: 2 x (3.6 + 3.4) x 2.4 = 33.6 m².
  • Ceiling: 3.6 x 3.4 = 12.24 m².
  • Openings: an 820 x 2040 mm door (1.67 m²) and an 1810 x 1200 mm window (2.17 m²).
  • Net area: 42.0 m².
A 3.6 by 3.4 metre bedroom unfolded into four walls 2.4 metres high and a ceiling, with a door and a window removed: 42 square metres net, 17 sheets of 2400 millimetre board or 11 sheets of 3600 millimetre board
A 3.6 by 3.4 metre bedroom unfolded into four walls 2.4 metres high and a ceiling, with a door and a window removed: 42 square metres net, 17 sheets of 2400 millimetre board or 11 sheets of 3600 millimetre board
sheets = round up (net area / sheet area x 1.10)
SheetAreaSheets for the bedroomAt an example priceBoard bought
1200 x 24002.88 m²17 (16.04 exact)A$340 at A$2048.96 m²
1200 x 36004.32 m²11 (10.69 exact)A$330 at A$3047.52 m²

On the 3.6 m walls a 3600 sheet runs corner to corner; on the 3.4 m walls it leaves a 200 mm offcut. Either way there is no butt joint in the middle of a wall.

With 2.7 m ceilings the walls grow to 37.8 m² and the net area to 46.2 m². In 3600 sheets that is 12; in 2700 sheets hung vertically it is 16, each running floor to ceiling.

How heavy the order is

Weight decides how many people you need and whether long sheets will make it through the house.

  • SafeWork SA's example safe work procedure is written around a 6 m x 1.2 m x 10 mm sheet weighing 49 kg. It plans a mechanical aid such as a vehicle-mounted hoist for unloading, a two-person team lift for carrying (three where practicable), and sheets stored flat, raised off the ground.
  • Gyprock gives a nominal weight of 5.7 kg/m² for Gyprock Plus and 7.1 kg/m² for its wet-area board, Aquachek 10 mm. A 6 m sheet of Plus is therefore about 41 kg, and of Aquachek about 51 kg.
OrderBoardAt 5.7 kg/m²At 6.8 kg/m² (SafeWork SA's sheet)
Bedroom, 17 x 240048.96 m²about 279 kgabout 333 kg
Bedroom, 11 x 360047.52 m²about 271 kgabout 323 kg
6.0 x 4.2 m living room, 11 x 600079.2 m²about 451 kgabout 539 kg

The living room example (2.4 m ceiling, a door and a 2400 x 2100 mm sliding door opening) has 67.45 m² net. Six-metre sheets suit its 6 m walls, but they need a clear, straight route from the truck; check doorways and hall corners before you order them.

Screws, tape and base coat

Screws follow the board maker's fixing centres and the frame spacing, so treat the calculator's default of 10 screws per m² of board as a starting point. For the bedroom it is 490 screws in 2400 sheets or 476 in 3600 sheets.

Jointing is done in stages, and Gyprock's own range lists base coats (Base Coat 20, 45, 60 and 90), numbered by working time in minutes, alongside separate topping compounds. The calculator's defaults are 121 m of tape and 37 litres of ready-mixed compound per 100 m² of board. The tape rate is the calculator's own estimate; the compound rate is converted from US data: USG gives about two 4.5 gallon pails of ready-mixed compound per 1,000 sq ft. For the bedroom that is about 51 m of tape and 15.5 litres of compound. If you use a powder base coat, replace the compound rate with the coverage printed on the bag.

Cornice is ordered by length: the bedroom's perimeter is 14 m, so order lengths that cover that plus the cuts at each corner.

Ceilings, wet areas and older homes

Ceilings. Gyprock recommends Plus for ceilings with joists at the standard 450 mm centres and Supaceil where joists are at up to 600 mm. Sheet the ceiling before the walls, so the wall sheets support its edges.

Wet areas. Gyprock lists Aquachek for bathrooms, laundries, en suites and toilets, and refers to the wet-area waterproofing requirements that apply on top of the board. Order wet-area board separately from the standard sheets.

Older homes. Re-sheeting often starts by removing old linings. SafeWork NSW says homes built before the late 1980s may contain asbestos, commonly in walls, ceilings, kitchens and bathrooms. Have old sheeting checked before you cut, drill or break it.

Frequently asked questions

How many sheets of plasterboard for a 3.6 x 3.4 m bedroom?

With 2.4 m ceilings, a door and a window, the walls and ceiling come to 42 m² net. With 10% extra that is 17 sheets of 2400 mm, or 11 sheets of 3600 mm hung horizontally.

How heavy is a 6 metre sheet of plasterboard?

SafeWork SA uses 49 kg for a 6 m x 1.2 m x 10 mm sheet. Gyprock's nominal weights put a 6 m sheet of Gyprock Plus at about 41 kg and of Aquachek wet-area board at about 51 kg. Plan a team lift for any long sheet.

Is it better to use 2400 or 3600 mm plasterboard?

Longer sheets mean fewer butt joints and usually a little less board: the bedroom takes 11 sheets of 3600 against 17 of 2400. Shorter sheets are lighter and easier to get into the room, which matters in tight hallways and upstairs.

What plasterboard goes on a ceiling with 600 mm joists?

Gyprock recommends Supaceil for ceiling joists at up to 600 mm centres, and Gyprock Plus for the standard 450 mm. Check the installation guide for the board you buy.

Sources and further reading

Open the Drywall Calculator

More Carpentry & Woodworking