United Kingdom version. Plasterboard in UK sizes: 2400 x 1200 mm boards, rooms in metres, screws per m², tape in metres and jointing compound in litres, prices in pounds. US version

Plasterboard Calculator (UK)

How many 2400 x 1200 plasterboards a room needs for walls and ceiling, less doors and windows, with drywall screws, joint tape and compound in metric.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Drywall Calculator?

UK plasterboard comes in 1200 mm wide sheets, 2400 mm long and in other lengths, in 9.5, 12.5 and 15 mm thicknesses. Boards are screwed to timber or metal studs and then either skimmed with a thin coat of finish plaster or taped and jointed. This version works in those sizes, with tape and compound rates converted from US USG rates.

A typical bedroom of 3.6 x 3.0 m with a 2.4 m ceiling, one door and one window has 39.5 m² to board. With 10% for cuts that is 16 boards, about 460 screws at 10 per m², 48 m of tape and about 15 litres of ready-mixed joint compound if you tape and joint instead of skimming.

Boards are heavy and awkward. HSE asks for plasterboard carried by hand to be a two-person job, with ceiling lifts for overhead boards and board lifters for the bottom row, and notes that special thermal or acoustic boards may weigh up to 50 kg each.

  • Walls, ceiling, openings, extra area and multiple identical rooms
  • Sheet sizes from 4x8 to 54 in x 12 ft and 1200 x 2400 to 3000 mm
  • Editable screw, tape and compound rates with pails and rolls
  • Board cost, imperial and metric with feet-inch input
  • Copy results and share a link with your inputs
Read the guide: How Much Drywall, Mud and Tape? Estimating a Room

Updated

How to use the Drywall Calculator

  1. Keep the units on metric and enter the room length, width and ceiling height in metres.
  2. Enter the door and window openings in mm and tick the ceiling if it is being boarded too.
  3. Pick 1200 x 2400 mm boards and set the price per board in pounds.
  4. Set the screws per m² from your board maker's fixing centres; tape and compound only matter if you tape and joint.

Worked examples

Double bedroom, walls and ceiling

Input

3.6 x 3.0 m, 2.4 m high, ceiling boarded, one 830 x 2020 mm door, one 1200 x 1050 mm window, 2400 x 1200 boards, 10% extra, £10 a board

Output

39.54 m² net; 16 boards (15.1 exact); 461 screws; about 48 m of tape and 14.6 L of compound (one 15 L tub); £160

Walls are 31.68 m² and the ceiling 10.8 m² before openings. If the room is being skimmed, ignore the tape and compound and order finish plaster instead.

Three bedrooms the same size

Input

As above, three rooms

Output

118.63 m² net; 46 boards; 1325 screws; 144 m of tape; about 44 L of compound

Entering the rooms together rounds once, so you buy 46 boards instead of 48 from three separate orders.

Studs at 400 mm centres

Input

Bedroom as above, 12.5 screws per m²

Output

576 screws instead of 461

Screw lines follow the studs, so closer studs mean more screws for the same board. If your board maker specifies 300 mm screw centres, a 2400 x 1200 board on studs at 600 mm takes 27 screws, about 9.4 per m²; on studs at 400 mm it takes 36, or 12.5 per m².

Background and insight

Wall area is the room perimeter times the height; the ceiling is length times width. Openings come off the total, and a waste allowance of 10 to 15% covers cut-offs at doors, windows and corners. Longer sheets reduce the number of butt joints, which are the hardest to finish, so a 12 ft room is often hung with 12 ft sheets even though the sheet count barely changes.

For finishing materials the calculator uses typical rates and labels them as such: about 32 screws per 4x8 sheet (one per square foot, from screws at 12 in centres on ceilings and 16 in on walls per GA-216 and the board makers' instructions), about 370 ft of paper tape per 1,000 square feet of board (USG's published coverage), and about 9.4 gallons of ready-mixed all-purpose compound per 1,000 square feet for taping and three coats. Lightweight and setting compounds cover differently, so edit the rate to suit.

Common use cases

  • Ordering board for a renovation

    Count sheets per room and add rooms of the same size before calling the supplier.

  • Basement finishing

    Estimate walls only, with tall or short sheets, for a basement with exposed or dropped ceilings.

  • Planning finishing labour

    Use tape and compound quantities to plan coats and buckets for a taping crew.

  • Comparing sheet sizes

    See how 4x8, 4x12 and 54 in sheets change the count and the number of joints.

Tips and limitations

  • Fix ceiling boards first, then wall boards, so the wall boards support the ceiling edges.
  • Use moisture-resistant board in bathrooms and behind kitchen sinks, and a cement or foam backer board in a tiled shower.
  • Stagger the joints between rows by at least one stud so they do not line up on the same timber.

Sources and further reading

  1. Construction manual handling: plasterboard installation, Health and Safety Executive. Two-person carrying, ceiling lifts, and boards of up to 50 kg each.
  2. The Building Regulations 2010, Schedule 1, legislation.gov.uk. Requirement E2: protection against sound within a dwelling-house.
  3. Sheetrock Brand Paper Joint Tape, USG. Source of the default tape rate, about 370 ft per 1,000 sq ft, converted to 121 m per 100 m².
  4. How much Sheetrock Brand UltraLightweight All Purpose Joint Compound do I need?, USG. About two 4.5 US gal pails per 1,000 sq ft of board, comparable to other USG ready-mixed compounds; converted here to 37 L per 100 m².

Frequently asked questions

How many sheets of plasterboard do I need for a room?

Add the wall area (perimeter times height) and the ceiling area in m², take off doors and large windows, add 10% and divide by 2.88 m² for a 2400 x 1200 board. A 3.6 x 3.0 m bedroom with a 2.4 m ceiling, a door and a window comes to 16 boards.

Should I use 9.5 mm or 12.5 mm plasterboard?

12.5 mm board spans further between studs or joists and gives better sound and fire performance than 9.5 mm, which needs closer framing. The board maker states the maximum framing centres for each thickness, so check them against your stud or joist spacing.

Do I need to tape and joint, or can I skim?

Either finishes plasterboard. Skimming puts a 2 to 3 mm coat of finish plaster over the whole board and usually needs a plasterer; taping and jointing fills only the joints and screw heads with compound, which is easier to do yourself. Use tapered-edge boards for taping and square-edge boards for skimming.

How many screws does a plasterboard need?

It depends on the fixing centres your board maker specifies and the stud spacing. At 300 mm screw centres on studs at 600 mm, a 2400 x 1200 board takes 27 screws, about 9.4 per m²; at 400 mm studs it is 36. Check the maker's centres for ceilings separately.

Do internal walls need sound insulation?

In new homes and conversions, requirement E2 of Schedule 1 to the Building Regulations 2010 asks for internal walls between a bedroom or a room containing a WC and other rooms to provide reasonable resistance to sound. In practice that means mineral wool in the stud cavity and a suitable board.

Is there an in-depth guide to the Drywall Calculator?

Yes. “How Much Drywall, Mud and Tape? Estimating a Room” covers the background, how it works, common pitfalls and worked examples. Read the full guide.