Stud Wall and Timber Frame Calculator (UK)

Count CLS studs, sole and head plates and lintels for a timber stud partition or frame panel at 400 or 600 mm centres, with door openings and boards in mm.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Wall Framing Calculator?

UK stud walls are measured in millimetres: CLS timber is sold in 38 x 63 and 38 x 89 mm sections, and timber frame panels use deeper studs such as 38 x 140 mm where the frame design calls for them. Studs are set out at 600 or 400 mm centres so that the long edges of a 1200 mm wide plasterboard land on a stud. This version starts in those units: a 3.6 m partition, 2.4 m high, with one door.

The count covers the studs on layout, the extra studs either side of each opening, short studs over the lintel, and the sole plate and head plate. It does not count noggins. Add those by hand: a row at mid-height on tall walls, at board joints that do not fall on a stud, and behind anything you will hang, such as radiators, wall cupboards and a TV bracket.

For a load-bearing wall or a timber frame panel, the lintel sizes, stud grade and fixings come from the frame designer or structural engineer, and building control will check them. The calculator only turns those choices into a cutting and buying list.

  • Feet-inch-fraction or metric input with live echo of the parsed value
  • Layout studs, opening deductions, kings, jacks and cripples
  • Corner and intersection studs set to your framing style
  • Plate linear feet and stock pieces, header lengths, sheathing sheets
  • Itemised stud table, copy and share link
Read the guide: How Many Studs Do I Need? Wall Framing Takeoffs Explained

Updated

How to use the Wall Framing Calculator

  1. Leave the units in metric and enter the wall length and the height from floor to the underside of the ceiling.
  2. Pick 600 mm centres for most partitions, 400 mm where the wall will be tiled or carry heavy units, and enter 38 mm as the timber thickness.
  3. Use a single top plate for a partition; a timber frame panel with a head binder counts as two.
  4. Enter the door lining opening (for example 830 x 2020 mm for a 762 mm leaf) and any window openings with their sill height.

Worked examples

Bedroom partition, 3.6 m long at 600 mm centres

Input

3.6 x 2.4 m, 38 mm CLS at 600 mm, single head plate, one 830 x 2020 mm door opening, 10% extra

Output

13 studs to buy (11 net) at 2324 mm; 7.2 m of plate (two 3.6 m lengths); lintel 906 mm; 4 boards for one face

Seven layout positions, minus one inside the doorway, plus two full-height studs and two door studs beside the opening and one short stud over the head. Noggins are extra.

The same partition at 400 mm centres

Input

As above, studs at 400 mm

Output

16 studs to buy (14 net) at 2324 mm

Three more studs for a stiffer wall that suits tiling or 9.5 mm board. Plates, lintel and boards stay the same.

Timber frame external panel with a window

Input

4.8 x 2.4 m, 38 x 140 mm at 600 mm, head plate plus head binder, one corner, one T junction, 1200 x 1050 mm window at 900 mm sill, two-ply 190 mm lintel

Output

19 studs (17 net) at 2286 mm; 14.4 m of plate in three 4.8 m lengths; lintel 2 pieces of 1276 mm; 5 sheathing boards

The head binder adds a third plate run, so the stud is 114 mm shorter than the wall. Panels from a frame supplier arrive with their own cutting list; use this to check a quote or a self-build panel.

Background and insight

Studs are laid out from one end of the wall at a fixed spacing, so a wall of length L holds ceil(L / s) + 1 studs including the one at the far end: ten studs for a 12 ft wall at 16 in. Sixteen-inch layout lines up with 4 ft sheets every third stud; 24 in layout, used in advanced framing, lines up every second stud and saves roughly a third of the studs. Metric frames use 400 or 600 mm for the same reason with 1200 mm sheets.

A standard 8 ft wall is 97-1/8 in from floor to the top of the double top plate: three plates at 1-1/2 in plus a 92-5/8 in precut stud. That leaves room for a 96 in sheet of drywall on the wall plus the thickness of the ceiling board. Each opening gets a king stud on both sides running full height and one or more jack (trimmer) studs carrying the header; short cripples fill the layout above the header and below a window sill. Header size depends on the opening width and the load above and comes from a header span table such as IRC Table R602.7(1).

Common use cases

  • Ordering lumber for a room addition

    Total studs, plates and headers wall by wall before calling the yard.

  • Basement and garage partitions

    Count studs for non-bearing walls with a single top plate or 24 in spacing.

  • Bidding framing labour

    Use the stud and opening counts as the basis for a per-piece or per-opening price.

  • Learning wall anatomy

    See how kings, jacks, cripples and corner studs add up and where the extra studs go.

Tips and limitations

  • Mark stud positions on the floor and ceiling before you fix the sole and head plates, so the board edges fall on a stud from the first sheet.
  • Keep electrical cables in the safe zones and run them through holes drilled near the centre of the stud, not in notches.
  • Order CLS in lengths that cut cleanly: two 1.2 m noggins or one 2.3 m stud from a 2.4 m length.

Sources and further reading

  1. The Building Regulations 2010, Schedule 1, legislation.gov.uk. Part A (structure) and requirement E2 on sound resistance of internal walls.
  2. Structure: Approved Document A, GOV.UK
  3. NHBC Standards 6.3.9: Construction of timber partitions, NHBC

Frequently asked questions

What size timber is used for stud walls in the UK?

CLS timber, planed with rounded edges, is sold in 38 x 63 mm and 38 x 89 mm sections for partitions. External timber frame panels use the stud size on the frame drawings, and a deeper stud such as 38 x 140 mm leaves room for more insulation. Structural walls use the strength class on the drawings, such as C16 or C24.

Should studs be at 400 or 600 mm centres?

Both divide into a 1200 mm board, so either works for the board edges. Plasterboard makers publish the maximum stud centres for each board thickness, and thinner boards, tiled walls and walls carrying kitchen units call for closer studs. Check the board maker's data before choosing 600 mm.

How many noggins does a stud wall need?

The calculator does not count them. As a starting point, one row at mid-height on walls above about 2.4 m, extra noggins at horizontal board joints and wherever you will fix radiators, basins, cupboards or handrails. Each row needs one piece per stud bay.

Do I need building regulations approval for a stud wall?

Removing or adding a load-bearing wall is building work that needs building control. In new homes and conversions, requirement E2 of Schedule 1 to the Building Regulations 2010 asks for internal walls between a bedroom or a room containing a WC and other rooms to provide reasonable resistance to sound, which affects the board and insulation you choose.

What is a head binder in a timber frame wall?

A second timber laid on top of the panel head plates, lapping the joints between panels to tie them together. Set the top plates to two so the stud length and the plate total include it.

How long should a timber lintel be?

The opening width plus the bearing on the studs at each side. With one 38 mm stud under each end, a 1200 mm window needs a 1276 mm lintel; the depth and the number of plies come from the frame design.

Is there an in-depth guide to the Wall Framing Calculator?

Yes. “How Many Studs Do I Need? Wall Framing Takeoffs Explained” covers the background, how it works, common pitfalls and worked examples. Read the full guide.