South Africa version. Starts from monthly kWh on a South African bill, 550 W panels and a 48 V battery for load shedding, and explains when a system must be registered as an SSEG. US version
Solar Panel and Battery Calculator (South Africa)
How many solar panels and how much battery a South African home needs, from kWh on the Eskom or municipal bill, with the SSEG registration rules that apply.
The interactive tool loads here when JavaScript runs.
About this toolWhat is the Solar Panel Calculator?
Many South African home systems are hybrid systems: panels, an inverter and a battery that carries the house through load shedding while the grid stays connected. Start with the monthly kWh on your Eskom or municipal account, a panel size such as 550 W, and how much of a day the battery should cover. This version opens on 600 kWh a month and half a day of battery.
Peak sun hours are where most estimates go wrong. Use the European Commission's PVGIS tool, which covers any location worldwide, to look up the solar energy on a tilted panel at your address and month, and enter it here. The table under the result shows how the panel count changes between 2 and 7 sun hours, so you can compare a winter month with the yearly average.
Registration is the local rule people miss. Eskom says households and small businesses under 100 kVA must register a grid-tied system even if it never exports, with a Certificate of Compliance, an NRS 097-2-1 inverter certificate and an embedded generation installation report. Fully off-grid systems are exempt but need a declaration form.
- Daily, monthly or yearly kWh input
- User-supplied peak sun hours with guidance on PVWatts and PVGIS
- Panel count, array kW and expected production
- Battery bank for days of autonomy at 12, 24 or 48 V
- MPPT charge controller current with 125% margin
- Panels-versus-sun-hours table
Updated
How to use the Solar Panel Calculator
- Enter your energy use in kWh per day, month or year. A year of utility bills gives the best figure.
- Enter peak sun hours for your site from PVWatts or PVGIS (worst month for off-grid, annual average for grid-tied).
- Keep 14% losses unless you know better, and enter the panel wattage you plan to buy.
- For a battery system, enter days of autonomy, bank voltage, usable depth of discharge and inverter efficiency. Set days to 0 for a grid-tied system.
- Read the panel count, array kW, expected output, battery size and charge controller rating.
Worked examples
Covering a 600 kWh a month house on paper
Input
600 kWh per month, 5 peak sun hours, 14% losses, 550 W panels, no battery
Output
4.59 kW minimum; 9 panels = 4.95 kW; about 21.3 kWh a day at 5 sun hours
This matches the energy over the day, not the timing: most of a household's evening use still comes from the grid or a battery. The 5 sun hours here are an assumed input; take your own from PVGIS.
Hybrid system for 12 kWh a day with half a day of battery
Input
12 kWh per day, 5 sun hours, 14% losses, 550 W panels, 0.5 days at 48 V, 80% depth of discharge, 95% inverter
Output
6 panels = 3.3 kW; 7.89 kWh battery (164.5 Ah at 48 V); MPPT 85.9 A
Half a day of storage covers an evening and a load-shedding block. At 4 sun hours, a typical winter assumption to test, the same house needs 7 panels (3.85 kW).
Off-grid weekend cabin
Input
4 kWh per day, 4 sun hours, 14% losses, 550 W panels, 2 days at 48 V, 90% depth of discharge, 95% inverter
Output
3 panels = 1.65 kW; 9.36 kWh battery (194.9 Ah at 48 V); MPPT 43.0 A
Two days of autonomy carries the cabin through cloudy weather. Because it has no connection to Eskom, it does not need SSEG registration, but Eskom asks direct customers for an off-grid declaration and the wiring must still comply with SANS 10142-1.
Background and insight
A solar panel's rating is its output at standard test conditions: 1,000 W/m² of sunlight at 25 °C cell temperature. Peak sun hours express a site's daily solar energy on the panel as the number of hours of that standard sun: 4.5 kWh/m²/day is 4.5 peak sun hours. The array size follows directly: kW = daily kWh ÷ (peak sun hours × (1 − losses)). 30 kWh a day at 4.5 hours and 14% losses needs 7.75 kW, which is 20 panels of 400 W.
System losses cover everything between the nameplate and your meter: soiling, shading, wiring, mismatch, inverter conversion, cell temperature and degradation. PVWatts uses 14% as its default total. Hot climates and dusty sites run higher; carefully designed systems with microinverters and clean panels can run lower.
Peak sun hours vary with location, tilt and season, so this tool does not guess them. Use PVWatts or the NSRDB from the National Laboratory of the Rockies (formerly NREL) for the US, or the European Commission's PVGIS for Europe, Africa and Asia, and read the value for your tilt. For grid-tied systems the annual average is right; for off-grid, design to the worst month you need to cover. Battery sizing is Wh = daily Wh × days ÷ (depth of discharge × inverter efficiency), and MPPT controller output current is array watts ÷ battery voltage, with a 25% margin in line with the NEC 690.8 practice of sizing PV circuits at 125% of their maximum current.
Common use cases
Quotes sanity check
Compare an installer's proposed system size with what your usage and sun hours call for.
Off-grid design
Size panels, battery and controller together for a cabin, van, boat or remote monitoring site.
Backup planning
Work out how much battery and solar keep essential loads running through a multi-day outage.
Roof space planning
Turn a kW target into a panel count to see whether it fits.
Tips and limitations
- Look up your own sun hours for the worst month you want to cover. A design that works in December can fall short in June.
- Ask for the inverter's NRS 097-2-1 type test certificate before you buy; Eskom's compliance procedure makes no concession for non-compliant inverters.
- Eskom residential customers with grid-tied generation must be on a time-of-use tariff (Homeflex), so plan battery use around the peak periods on that tariff.
- Eskom's SSEG brochure says you apply to NERSA or to your local utility depending on size, so if a municipality supplies your electricity, ask it for its own process.
Sources and further reading
- Small-scale embedded generation (SSEG), Eskom Distribution. Registration for grid-tied systems, exemption for fully off-grid systems, and the documents an application needs.
- Application form for small-scale embedded generation (2025 version 2), Eskom Distribution. NRS 097-2-1 inverter compliance, point of isolation and anti-islanding to SANS 10142-1, EGI report; NERSA approval above 100 kW.
- Management of certificates of compliance for electrical installations (240-170000465, revision 3), Eskom Distribution. Grid-tied and hybrid systems must be registered even if non-exporting; off-grid systems need a customer declaration.
- Tariffs and Charges Booklet 2026/2027, Eskom Distribution. Homeflex: a time-of-use tariff is mandatory for residential customers with grid-tied generation.
- Small-scale embedded generators (brochure), Eskom Distribution. Apply with NERSA or with your local utility depending on size; exported energy can offset use through net-billing (Gen-offset), wheeling and banking agreements, T&Cs apply.
- PVGIS: Photovoltaic Geographical Information System, European Commission Joint Research Centre
Frequently asked questions
Do I have to register my solar system in South Africa?
If it is connected to the grid, yes. Eskom's SSEG page says households and small businesses under 100 kVA must register with Eskom even if they do not export, and systems above 100 kVA up to 1 MW also need NERSA registration. If a municipality supplies you, ask it for its process.
What documents does Eskom ask for?
A valid Certificate of Compliance signed by a registered person, an inverter type test certificate showing NRS 097-2-1 compliance, and an embedded generation installation (EGI) test report, which Eskom now accepts signed by a registered Installation Electrician or Master Installation Electrician as well as by an ECSA-registered professional. The application form lists the exact items.
Is an off-grid system exempt?
Yes, provided it is fully independent of Eskom's supply. Eskom still asks its direct customers to submit a declaration form, and the installation must comply with the Occupational Health and Safety Act and SANS 10142-1.
Can I sell surplus solar power back?
Eskom's SSEG brochure says exported energy can offset consumption through net-billing (Gen-offset), wheeling and banking agreements, subject to terms. A residential customer with grid-tied generation must be on a time-of-use tariff such as Homeflex.
How many 550 W panels do I need for 600 kWh a month?
At 5 peak sun hours and 14% losses, 9 panels (4.95 kW) produce about the same energy as 600 kWh a month. With fewer sun hours you need more; the table under the result shows the count at each level from 2 to 7 hours.
Where do I find peak sun hours for my town?
The European Commission's free PVGIS tool gives solar radiation and PV performance for any location worldwide, including monthly solar energy on a tilted surface. Enter the kWh/m² per day for your design month as peak sun hours.
Is there an in-depth guide to the Solar Panel Calculator?
Yes. “How Many Solar Panels Do I Need? Sizing Arrays and Batteries” covers the background, how it works, common pitfalls and worked examples. Read the full guide.
Related Tools You May Like