Flow Rate Converter

Convert flow rate between L/s, L/min, m³/h, US gpm, gph and cfm with exact gallon and cubic foot definitions, worked through for pumps, showers and ducts.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Flow Rate Converter?

Enter one volumetric flow rate and read it in litres per second, litres per minute, cubic metres per hour, cubic metres per second, US gallons per minute, gallons per hour and cubic feet per minute at the same time. Selecting a target unit prints the steps for that pair, so 100 gpm is shown as 100 × 3.785411784 ÷ 60 = 6.309 L/s before it becomes 22.71 m³/h.

Flow units cluster by trade. Pump curves and plumbing fixtures in North America are labelled in gpm, European pump and pipe catalogues use m³/h, HVAC airflow lives in cfm or m³/h depending on the market, and process engineering tends to L/s. The factors are exact because the underlying volumes are: a US gallon is 3.785411784 L and a cubic foot is 28.316846592 L, both by definition, so 1 cfm is 1.699 m³/h with no measurement uncertainty involved.

Conversions happen in your browser only; the numbers never leave your device. Each working step cites the exact volume definition it uses, the report bar below exports the whole table to CSV or PDF, and a share link rebuilds the conversion for whoever opens it.

  • One value converted across seven flow units simultaneously
  • Worked steps for any target pair, citing exact gallon and cubic foot volumes
  • US gpm, gph and cfm alongside L/s, L/min, m³/h and m³/s
  • CSV and PDF export of the table from the report bar
  • Browser-only conversion with a shareable link; nothing is uploaded
Read the guide: Unit Conversion Factors: Exact Definitions, Gallons and Temperature Offsets

Updated

How to use the Flow Rate Converter

  1. Type the flow rate from your pump curve, fixture label, fan spec or problem sheet.
  2. Choose the unit it is in, for example US gpm or cfm.
  3. Read the value in all seven flow units in the results table.
  4. Select a target unit to see the step-by-step arithmetic with the exact gallon or cubic foot definition.
  5. Export the table as CSV or PDF from the report bar, or copy the share link.

Worked examples

Pump curve to metric

Input

100 gpm

Output

6.309 L/s = 22.71 m³/h = 13.37 cfm

100 × 3.785411784 ÷ 60 = 6.309 L/s, and multiplying by 3.6 gives 22.71 m³/h. The cfm figure follows from the cubic foot holding 7.4805 US gallons.

US showerhead maximum

Input

2.5 gpm

Output

9.46 L/min = 0.158 L/s

2.5 × 3.785411784 = 9.46 L/min, the federal maximum flow for showerheads sold in the US. European fittings quote the L/min figure directly.

Fan airflow to metric

Input

1,000 cfm

Output

471.9 L/s = 1,699 m³/h

1,000 × 28.316846592 ÷ 60 = 471.9 L/s, then × 3.6 = 1,699 m³/h. The 1.699 ratio between m³/h and cfm is worth memorising for duct work.

One cubic metre per hour

Input

1 m³/h

Output

16.67 L/min = 4.403 gpm = 0.589 cfm

1,000 L spread over 60 minutes is 16.67 L/min. Dividing by 3.785411784 gives 4.403 gpm, the figure to look for on a US pump curve.

Background and insight

A volumetric flow rate is a volume passing a point per unit time, and every unit here is just a different volume over a different time. That makes the conversions pure ratios: gpm to L/min multiplies by 3.785411784, cfm to L/s multiplies by 28.316846592 and divides by 60, and m³/h to L/s divides by 3.6. The traps are almost always the gallon, since the imperial gallon is 4.54609 L and would shift every figure by 20 percent, and the minute-versus-hour denominators.

Plumbing is where most people meet these units. US federal law has capped showerheads at 2.5 gpm since 1994, which is 9.46 L/min, and faucet aerators are commonly 1.0 to 1.5 gpm. A pump that must fill a 1,000 L tank in 20 minutes needs 50 L/min, which reads as 13.2 gpm on a North American pump curve or 3.0 m³/h on a European one. Matching a pump to a duty point is largely an exercise in getting all the catalogue figures into one unit first.

Air handling has its own convention. Duct and fan sizing in North America is done in cfm, while European practice uses m³/h or L/s, and ventilation standards quote fresh-air requirements per person in either. The same fan moving 1,000 cfm is moving 1,699 m³/h or 472 L/s. Because air is compressible, cfm figures for compressors are often given at stated reference conditions; this converter handles the volumetric arithmetic, and pressure and temperature corrections sit on top of it.

Common use cases

  • Pump selection

    Put a duty point in L/min or m³/h next to North American pump curves labelled in gpm.

  • Plumbing fixtures

    Compare showerhead, faucet and irrigation flow labels across gpm and L/min markets.

  • HVAC and ventilation

    Convert fan and duct airflow between cfm, L/s and m³/h when specs and standards disagree.

  • Process and lab work

    Normalise flow meters, rotameters and datasheet figures into one unit before sizing lines.

Tips and limitations

  • Check which gallon a figure uses: this tool's gpm is the US gallon, 3.785411784 L; an imperial gpm is 20 percent larger.
  • cfm to m³/h is a factor of 1.699; a quick mental double-then-subtract-15-percent gets you close.
  • Watch the denominator: confusing gph with gpm, or m³/h with m³/s, shifts a result by a factor of 60 or 3,600.
  • Compressor cfm ratings often refer to stated reference conditions; convert the volume arithmetic here and apply pressure corrections separately.
  • For tank-filling problems, convert the required volume and time to the pump catalogue's unit before reading the curve.

Sources and further reading

  1. NIST Special Publication 811: Guide for the Use of the International System of Units, NIST. Exact gallon and cubic foot definitions behind the factors
  2. Volumetric flow rate, Wikipedia. Definition and relation to mass flow
  3. The International System of Units (SI Brochure), BIPM. The litre and the cubic metre per second as coherent units

Frequently asked questions

How many litres per minute is 1 gpm?

One US gallon per minute is 3.785411784 L/min exactly, because the US gallon is defined as 3.785411784 L. An imperial gallon per minute would be 4.54609 L/min; this converter uses the US gallon.

How do I convert cfm to m³/h?

Multiply by 1.699011. A cubic foot is 28.316846592 L exactly, so 1 cfm is 28.3168 L/min, which is 1.699 m³/h. Going the other way, divide the m³/h figure by 1.699.

What flow rate is a typical shower?

US federal rules cap showerheads at 2.5 gpm, which is 9.46 L/min; many modern low-flow heads are 1.8 or 2.0 gpm. European fittings are labelled directly in L/min, commonly 8 to 12 L/min for mixer showers.

Is cfm only for air?

No, it is a volume rate like any other and the conversion is identical for any fluid. In practice cfm is the customary unit for fans, ducts and compressors, while liquids in the same markets are quoted in gpm.

What is the difference between gpm and gph?

Only the time base: gallons per minute versus gallons per hour, a factor of exactly 60. Fuel nozzles and drip irrigation often use gph while pumps use gpm, so the two get mixed up in sizing calculations.

Does this convert mass flow like kg/s?

No. These are volumetric units. To get mass flow, multiply the volumetric rate by the fluid density; 1 L/s of water at about 1 kg/L is roughly 1 kg/s, but air and oils differ a lot.

Is there an in-depth guide to the Flow Rate Converter?

Yes. “Unit Conversion Factors: Exact Definitions, Gallons and Temperature Offsets” covers the background, how it works, common pitfalls and worked examples. Read the full guide.