United Kingdom version. Checks a ramp against Approved Document M in metric: Volume 1 (M4(1)) for the approach to a home and Volume 2, Table 1 for buildings other than dwellings. US version

Ramp Gradient Calculator (Approved Document M)

Ramp length, flights and landings from the rise, checked against Approved Document M: 1:12 to 1:20 by going for public buildings and 1:12 or 1:15 for a home.

The interactive tool loads here when JavaScript runs.

About this tool

What is the Ramp Calculator?

In England the guidance for ramps is Approved Document M. Volume 2, for buildings other than dwellings, ties the gradient to the going of each flight: 1:12 is allowed for a going of up to 2 m, 1:15 up to 5 m and 1:20 up to 10 m, with straight-line interpolation between (1:14 for a 4 m going), and no flight may rise more than 500 mm. Volume 1, for the approach to an M4(1) visitable dwelling, is simpler: flights up to 1:15 may be 10 m long and flights up to 1:12 only 5 m. If your planning permission requires M4(2) or M4(3), Diagram 2.1 applies instead: at 1:12 a flight may only be 2 m long.

Pick the rule, enter the total rise from the path to the threshold and the gradient you can fit, and the tool splits the ramp into flights, adds the landings the rule asks for (1.2 m at the head and foot and 1.5 m between flights in Volume 2, rising to 1.8 x 1.8 m passing places when there are three or more flights) and gives the straight footprint and handrail length. Each limit is checked and the clause shown, so you can see whether a gentler gradient with fewer landings beats a steeper one.

  • ADA 2010 Section 405, existing-site Table 405.2, IRC R311.8 and custom slopes
  • Run, sloped length, angle, percent and number of runs
  • Landings and straight footprint, handrail length per side
  • Pass or fail checks with section numbers
  • Inches or millimetres, copy and share link
Read the guide: ADA Ramp Rules: Slope, Rise, Landings and Handrails

Updated

How to use the Ramp Calculator

  1. Choose Approved Document M Vol 1, M4(1) for the approach to a house or flat, or Vol 2 for shops, offices and other non-domestic buildings.
  2. Enter the total rise in millimetres, measured from the bottom of the ramp to the top of the threshold.
  3. Enter the gradient as a ratio (15 for 1:15), a percentage or an angle.
  4. Enter the clear width. Vol 2 asks for 1.5 m between walls, upstands or kerbs; Vol 1 asks for 900 mm.
  5. Leave the landing blank to use the rule's lengths, or enter your own.

Worked examples

Approach to a home: 300 mm rise at 1:15

Input

Approved Document M Vol 1, rise 300 mm, 1:15, width 900 mm

Output

One flight, 4.5 m horizontal run; 6.9 m footprint with 1.2 m landings at each end

At 1:15 a flight may be up to 10 m long, so the whole rise fits in one flight. At 1:12 the run drops to 3.6 m and is still within the 5 m limit for that gradient.

Shop entrance: 450 mm rise at 1:15

Input

Approved Document M Vol 2, rise 450 mm, 1:15, width 1500 mm

Output

Two flights of 225 mm over 3.375 m; 10.65 m footprint; steps also needed

Table 1 limits a 1:15 flight to a 5 m going and 333 mm of rise, so the ramp needs a 1.5 m intermediate landing. Because the total rise is over 300 mm, clearly signposted steps must be provided as well (1.26n).

Steeper is not always shorter: 450 mm at 1:12

Input

Approved Document M Vol 2, rise 450 mm, 1:12, width 1500 mm

Output

Three flights of 150 mm; 11.4 m footprint with 1.8 m passing-place landings (1.26j)

At 1:12 a flight may only have a 2 m going (about 166 mm of rise), so the ramp needs two intermediate landings. With three flights those landings must be passing places at least 1.8 x 1.8 m, so the ramp ends up longer overall than the 1:15 design.

Background and insight

The rules come from Section 405 of the 2010 ADA Standards. The running slope may not be steeper than 1:12 (405.2) and the cross slope not steeper than 1:48 (405.3). Clear width between handrails is at least 36 inches (405.5). The rise of any single run is 30 inches at most (405.6). Landings at the top and bottom of every run are at least as wide as the ramp and at least 60 inches long, and a landing where the ramp changes direction is at least 60 by 60 inches (405.7). Runs that rise more than 6 inches need handrails on both sides (405.8), mounted 34 to 38 inches high (505.4) and extending 12 inches beyond the top and bottom of the run (505.10).

Existing sites get limited relief under Table 405.2 when space does not allow 1:12: a slope between 1:12 and 1:10 is allowed for a rise of 6 inches at most, and between 1:10 and 1:8 for a rise of 3 inches at most. Nothing steeper than 1:8 is permitted.

Homes follow the International Residential Code where adopted. IRC R311.8 sets a maximum ramp slope of 1:12, allowing 1:8 only where 1:12 is technically infeasible, requires 36 by 36 inch landings at the top and bottom, at doors and at turns, and requires a handrail on at least one side of ramps steeper than 1:12. Many people still build home ramps to ADA dimensions because they are easier to use. Loading ramps for vehicles and equipment are outside these rules; follow the equipment maker's maximum angle.

Common use cases

  • Home access

    Size a ramp for a wheelchair user before buying a modular kit or lumber.

  • Small businesses

    Check an entrance ramp against ADA 405 before a contractor quote or an accessibility review.

  • Thresholds and small changes in level

    Use the existing-site table for short ramps of a few inches where space is tight.

  • Sheds, trailers and loading docks

    Work out the length for a mower, cart or hand truck at any slope.

Tips and limitations

  • Where the total rise of a public building approach is over 2 m, Volume 2 asks for an alternative such as a lift for wheelchair users.
  • A kerb at least 100 mm high, in a contrasting colour, is needed on the open side of a ramp or landing (Vol 2, 1.26m).
  • Handrails go on both sides, 900 to 1000 mm above the ramp surface, and extend at least 300 mm beyond the top and bottom.
  • Scotland, Wales and Northern Ireland have their own technical standards and guidance, so check the version that applies to the site.

Sources and further reading

  1. Approved Document M, Volume 2: Buildings other than dwellings (2015 edition incorporating 2020 and 2024 amendments), Ministry of Housing, Communities and Local Government. Ramped access 1.19 to 1.26, Table 1 limits for ramp gradients, passing places 1.26j, handrails 1.37.
  2. Approved Document M, Volume 1: Dwellings (2015 edition incorporating 2016 amendments), Ministry of Housing, Communities and Local Government. External ramps on the approach to an M4(1) dwelling, paragraph 1.7; M4(2) and M4(3) ramps, paragraph 2.10 and Diagram 2.1.
  3. Access to and use of buildings: Approved Document M, GOV.UK

Frequently asked questions

What is the maximum ramp gradient under Part M?

1:12, and only for a flight with a going of up to 2 m. Approved Document M Vol 2, Table 1 allows 1:15 for up to 5 m and 1:20 for up to 10 m, interpolating between them. Anything 1:20 or steeper on an approach counts as a ramp.

How long can a ramp be before it needs a landing?

Under Vol 2, no flight may have a going over 10 m or a rise over 500 mm, and the going limit tightens as the ramp gets steeper (2 m at 1:12, 5 m at 1:15). Intermediate landings must be at least 1.5 m long, or 1.8 x 1.8 m passing places when the ramp has three or more flights (1.26j). Under Vol 1 for an M4(1) home, flights up to 1:15 can be 10 m and up to 1:12 can be 5 m, with 1.2 m landings. If your planning permission requires M4(2) or M4(3), Diagram 2.1 applies instead: at 1:12 a flight may only be 2 m long.

How wide does a disabled access ramp need to be in the UK?

At least 1.5 m surface width between walls, upstands or kerbs for buildings other than dwellings (Vol 2, 1.26e), and at least 900 mm clear for every flight on the approach to a dwelling (Vol 1, 1.7b).

Do I need steps as well as a ramp?

For buildings other than dwellings, yes, once the rise of the ramp is more than 300 mm: Vol 2 asks for clearly signposted steps in addition, because some people with walking difficulties find steps easier and safer than a long slope.

Does a wheelchair ramp at my house need building regulations approval?

A ramp built as part of new work that has to meet Part M follows Volume 1. A ramp added to an existing home may need planning permission depending on its height and position, so check with your council's building control and planning teams before building.

What gradient is 1:12 in degrees and percent?

1:12 is 8.33%, about 4.76 degrees. 1:15 is 6.67% (3.81 degrees) and 1:20 is 5% (2.86 degrees). The tool converts a ratio, percentage or angle for you.

Is there an in-depth guide to the Ramp Calculator?

Yes. “ADA Ramp Rules: Slope, Rise, Landings and Handrails” covers the background, how it works, common pitfalls and worked examples. Read the full guide.