Bolt Torque for MS and HT Bolts: Nm, kgf·m and Preload

Tightening torque in Nm and kgf·m for MS and HT bolts by property class (IS 1367 Part 3), why oil changes the answer, and how IS 4000 HSFG bolts are tensioned.

By · · 10 min read

Illustration for the Bolt Torque Calculator guide

India edition. Written for Indian workshops and sites: MS and HT bolts read as IS 1367 (Part 3) property classes, torque in N·m and kgf·m, and HSFG bolts to IS 3757 tensioned by the IS 4000 methods instead of a torque chart. US edition

An M16 HT bolt of property class 8.8 with dry threads needs about 218 N·m, or 22.2 kgf·m, to reach 75% of its proof load and clamp the joint with 68.2 kN. An M16 MS bolt of class 4.6 needs only 84.6 N·m (8.63 kgf·m) for the same 75%. Use the HT figure on an MS bolt and it stretches far past yield. The Indian version of the Bolt Torque Chart Calculator works in N·m or kgf·m from the IS 1367 (Part 3) property classes. This guide shows how to use it on the shop floor, why oil on the threads matters more than the bolt grade, and why HSFG bolts in steel structures are not tightened from any chart.

MS, HT and the property class

"MS bolt" and "HT bolt" are trade names, not grades. The strength is the property class stamped on the head, and IS 1367 (Part 3) sets it. Its 2002 edition is identical with ISO 898-1:1999, so the classes and proof stresses are the same as everywhere else:

Shop nameProperty classProof stressProof load, M16 (156.7 mm²)
MS (mild steel)4.6225 MPa35.3 kN
HT8.8580 MPa up to M16, 600 MPa above90.9 kN
HT10.9830 MPa130.0 kN
Allen cap screw12.9970 MPa152.0 kN

The first number x 100 is the nominal tensile strength in MPa, and the second / 10 is the ratio of yield to tensile: 8.8 means 800 MPa tensile and 640 MPa yield. An 8.8 bolt carries about 2.6 times the clamp force of a 4.6 bolt of the same size. A bolt with no marking is of unknown strength and should not go into a structural or safety-critical joint.

Torque in Nm and kgf·m

The calculator uses the short-form equation T = K x F x d: nut factor times clamp force times nominal diameter. Some torque wrenches and older service manuals read in kgf·m. One kgf·m is 9.80665 N·m, so divide N·m by 9.81 to get kgf·m.

Example 1, a pump base on M16 bolts. M16 x 2, dry threads (K = 0.20), 75% of proof:

ClassClamp forceTorque
4.6 (MS)26.4 kN84.6 N·m (8.63 kgf·m)
8.8 (HT)68.2 kN218.1 N·m (22.24 kgf·m)

Now suppose the fitter has HT figures in mind and sets 22 kgf·m (215.7 N·m) on an MS bolt. Switch the calculator to preload from torque: 67.4 kN, 191% of the class 4.6 proof load and 179% of its yield. The bolt necks or the thread strips. On an 8.8 bolt the same 22 kgf·m is 74.2% of proof, right where it should be.

Example 2, a round 8 kgf·m on M12. A wrench set to 8 kgf·m (78.45 N·m) on an M12 class 8.8 bolt, dry: 32.7 kN, 66.9% of proof. The usual 75% target is 88.0 N·m or 8.97 kgf·m. Rounding a wrench setting down by 1 kgf·m costs about 11% of the clamp force.

Oil, grease and galvanising

Most of the torque is lost to friction under the nut and in the threads, so the thread condition decides the clamp force. The calculator's nut factors follow Shigley's table: 0.20 for zinc-plated or unknown-finish dry steel (0.30 for plain black-oxide bolts), 0.18 oiled and 0.12 with anti-seize.

Example 3, oiled threads. Fitters often oil threads to stop seizing. An M12 class 8.8 bolt reaches the same 36.7 kN preload at 79.2 N·m oiled instead of 88.0 N·m dry. Put the dry 88.0 N·m on oiled threads and the preload rises to about 40.7 kN, 83% of proof. With anti-seize the same 88.0 N·m gives 61.1 kN, 125% of proof: the bolt has yielded.

Hot-dip galvanised bolts, common on transmission towers, solar mounting structures and anything outdoors, behave differently again because zinc on the threads changes friction. If the supplier gives a nut factor or a torque for galvanised bolts, use it.

HSFG bolts: tension, not torque

High-strength friction grip (HSFG) bolts in steel structures are made to IS 3757 in property classes 8.8 and 10.9, sizes M16 to M36, and BIS certifies them with proof-load, tensile and hardness tests to IS 1367 (Part 3). The code for using them, IS 4000:1992, is clear on three points.

The required tension is close to the proof load. IS 4000 Table 3 gives the minimum bolt tension:

SizeClass 8.8Class 10.9
M1694.5 kN130 kN
M20147 kN203 kN
M24212 kN293 kN
M30337 kN466 kN
M36490 kN678 kN

These are essentially the full proof load of the bolt. For M20 class 8.8 the calculator gives a proof load of 146.9 kN, and at 100% of proof with dry threads that is 587.5 N·m (59.9 kgf·m). A general torque chart at 75% (440.6 N·m) would leave the joint about a quarter short.

Torque control is not the tightening method. IS 4000 tightens HSFG bolts by the part-turn method (snug tight, mark, then turn the nut by the angle in its Table 4) or by direct tension indication. Its foreword says direct tension indication replaced torque control. A torque wrench is used only for inspection, to catch gross under-tensioning, and the code requires the inspection wrench to be calibrated at least once a shift on sample bolts from the job.

Example 4, why torque alone fails. Take that M20 8.8 bolt and set a wrench to the 587.5 N·m that gives 147 kN dry. If the threads are lightly oiled (K = 0.18), the bolt reaches about 163 kN, 111% of proof; if they are rusty or galvanised and the real factor is 0.24, it reaches about 122 kN, 17% short of the IS 4000 minimum. The wrench clicks at the same setting both times.

Fully tensioned bolts are not reused. IS 4000 allows retensioning only once, in the same hole with the same grip, and says fully tensioned bolts must never be reused in another hole. The slip factor depends on the faying surfaces: its Annex C recommends 0.50 for blasted surfaces with loose rust removed and only 0.10 for blasted and hot-dip galvanised surfaces, so at the same bolt tension a galvanised friction joint carries far less load per bolt.

How to use the calculator on site

  • MS and HT bolts in machines and fabrication: choose the class, the thread condition and the unit (N·m or kgf·m), and aim at 75% of proof for joints you will open again.
  • Vehicles and equipment with a service manual: follow the manual. Use the calculator only to check that a figure looks sensible.
  • HSFG bolts to IS 3757: tension by IS 4000 and the project specification. Use the calculator to understand how far torque scatters.

These figures are for preliminary design and checking. For structural connections, lifting gear and pressure joints, follow the code and have the joint checked by a qualified engineer.

Tools for this job

The original guide to T = KFd gives the long-form equation and inch examples.

Frequently asked questions

What is the torque for an M16 HT bolt in kgf·m?

About 22.2 kgf·m (218.1 N·m) for a class 8.8 bolt with dry threads at 75% of proof load, giving 68.2 kN of clamp force. With oiled threads the same clamp needs about 20 kgf·m.

Can I use the HT torque on MS bolts?

No. In example 1, 22 kgf·m on an M16 class 4.6 bolt loads it to 191% of proof. Use the class 4.6 figure, 8.63 kgf·m, or change to class 8.8 bolts if the joint needs more clamp.

How do I convert kgf·m to N·m?

Multiply by 9.80665. So 8 kgf·m is 78.45 N·m and 22 kgf·m is 215.7 N·m. Divide N·m by 9.80665 to go the other way.

What tension does an M20 HSFG bolt need?

IS 4000:1992 gives a minimum of 147 kN for M20 class 8.8 and 203 kN for class 10.9. That is the full proof load, reached by the part-turn method or direct tension indication rather than by torque.

Can HSFG bolts be reused?

Not in another hole. IS 4000 allows a fully tensioned bolt to be retensioned only once, in the same hole and with the same grip.

Sources and further reading

Open the Bolt Torque Calculator

More Mechanical

Every tool in the Mechanical section, free and in your browser.